Systematic review and meta-analysis: diagnostic value of different ultrasound for benign and malignant thyroid nodules

Gland Surg. 2022 Jun;11(6):1067-1077. doi: 10.21037/gs-22-254.

Abstract

Background: Conventional ultrasound and contrast-enhanced ultrasound (CEUS) are commonly used in the diagnosis of benign and malignant thyroid nodules. However, the value of the two methods in the diagnosis of benign and malignant thyroid nodules remains controversial.

Methods: PubMed, Medline, EBSCO, Science Direct, Cochrane Library, China National Knowledge Infrastructure (CNKI) database and manual journal retrieval were searched from January 2000 to January 2022, to include research on conventional ultrasound or CEUS in the diagnosis of benign and malignant thyroid nodule related clinical studies. Meta-analysis was conducted using RevMan5.3 and Stata Corp to analyze the sensitivity and specificity of conventional ultrasound and CEUS in the diagnosis of benign and malignant thyroid nodules with 95% confidence interval (CI) as indicators. Heterogeneity of the results was evaluated by Q test and I2 in RevMan5.3. Deek's method was used to evaluate publication bias.

Results: A total of 1,378 nodules were included in 11 literatures, including 535 malignant thyroid nodules and 843 benign thyroid nodules. Heterogeneity tests conducted for CEUS diagnostic sensitivity of the 6 included literatures indicated that there was no heterogeneity among the study groups [Q=2.05, degree of freedom (df) =5.00, I2=0.00%, P=0.84]. The combined sensitivity was 0.87, with 95% confidence interval (CI): 0.82 to 0.90. Heterogeneity tests on the diagnostic specificity of CEUS of the six included literatures suggested that there was heterogeneity among the different study groups (Q=14.27, df =5.00, I2=64.96%, P=0.01). The combined specificity was 0.84 (95% CI: 0.78 to 0.89). Heterogeneity tests performed on the sensitivity of five conventional ultrasound diagnosis articles revealed that there was heterogeneity among different study groups (Q=13.62, df =4.00, I2=70.64%, P=0.01). The combined sensitivity was 0.86 (95% CI: 0.78 to 0.92). Heterogeneity tests on the specificity of conventional ultrasound diagnosis in five included literatures indicated that there was heterogeneity among different study groups (Q=16.94, df =4.00, I2=76.39%, P=0.00). The combined specificity was 0.84 (95% CI: 0.75 to 0.90). There was no bias in the included literature.

Discussion: The sensitivity of CEUS in the diagnosis of benign and malignant thyroid nodules was slightly higher than that of conventional ultrasound, which provides a reference for the clinical diagnosis of benign and malignant thyroid nodules.

Keywords: Thyroid nodule; contrast-enhanced ultrasound (CEUS); conventional ultrasound; diagnosis; meta-analysis.