Optimization of the Chronic Kidney Disease-Peritoneal Dialysis App to Improve Care for Patients on Peritoneal Dialysis in Northeast Thailand: User-Centered Design Study

JMIR Form Res. 2022 Jul 6;6(7):e37291. doi: 10.2196/37291.

Abstract

Background: The prevalence of peritoneal dialysis (PD) in Thailand is increasing rapidly in part because of Thailand's Peritoneal Dialysis First policy. PD is a home-based renal replacement therapy in which patients with chronic kidney disease perform up to 4 exchanges of dialysate fluid per day in the peritoneal cavity. Overhydration is one of the most common complications in patients on PD and is associated with increased morbidity and mortality. To monitor hydration status, patients collect hydration metrics, including body weight, blood pressure, urine output, and ultrafiltration volume, from each dialysis cycle and enter this information into a PD logbook. This information is reviewed bimonthly at PD clinic appointments. The chronic kidney disease-PD (CKD-PD) app with near-field communication (NFC) and optical character recognition (OCR) was developed to automate hydration metric collection. The information was displayed in the app for self-monitoring and uploaded to a database for real-time monitoring by the PD clinic staff. Early detection and treatment of overhydration could potentially reduce the morbidity and mortality related to overhydration.

Objective: This study aims to identify usability issues and technology adoption barriers for the CKD-PD app with NFC and OCR and a monitoring system and to use this information to make rapid cycle improvements.

Methods: A multidisciplinary team of nephrologists, PD clinic nurses, computer programmers, and engineers trained and observed 2 groups of 5 participants in the use of the CKD-PD app with NFC and OCR and a monitoring system. The participants were observed using technology in their homes in 3 phases. The data collected included the Unified Theory of Acceptance and Use of Technology questionnaire, think-aloud observation, user ratings, completion of hydration metrics, and upload of hydration metrics to the central database. These results were used by the team between phases to improve the functionality and usefulness of the app.

Results: The CKD-PD app with NFC and OCR and a monitoring system underwent 3 rapid improvement cycles. Issues were identified regarding the usability of the NFC and OCR data collection, app stability, user interface, hydration metric calculation, and display. NFC and OCR improved hydration metric capture; however, issues remained with their usability. App stability and user interface issues were corrected, and hydration metrics were successfully uploaded by the end of phase 3. Participants' scores on technology adoption decreased but were still high, and there was enthusiasm for the self-monitoring and clinical communication features.

Conclusions: Our rapid cycle process improvement methodology identified and resolved key barriers and usability issues for the CKD-PD app with NFC and OCR and a monitoring system. We believe that this methodology can be accomplished with limited training in data collection, statistical analysis, and funding.

Keywords: UTAUT; Unified Theory of Acceptance and Use of Technology; barrier; computer program; dialysis; home monitoring; interface; internal medicine; kidney; mHealth; methodology; metric capture; mobile health; mobile phone; monitor; near-field communication; nephrologist; nephrology; peritoneal; peritoneum; process improvement; quality improvement; rapid cycle improvement; rapid cycle process improvement methodology; renal; usability.