Multidisciplinary Approach to Hemodynamic Management During High-Risk Ventricular Tachycardia Ablation

JACC Case Rep. 2022 Jun 1;4(11):639-644. doi: 10.1016/j.jaccas.2022.02.016.

Abstract

Percutaneous ventricular assist devices have been used for high-risk ventricular tachycardia ablation when hemodynamic decompensation is expected. Utilizing a case example, we present our experience with development of a coordinated, team-based approach focused on periprocedural management of patients with high-risk ventricular tachycardia. (Level of Difficulty: Advanced.).

Keywords: AHD, acute hemodynamic decompensation; CPO, cardiac power output; HR-VTA, high-risk ventricular tachycardia ablation; ICD, implantable cardioverter-defibrillator; LV, left ventricular; MCS, mechanical circulatory support; SVO2, mixed venous oxygen saturation; VT, ventricular tachycardia; VTA, ventricular tachycardia ablation; ablation; hemodynamics; multidisciplinary care; pVAD, percutaneous ventricular assist device; percutaneous mechanical circulatory support; ventricular tachycardia.

Publication types

  • Case Reports