Comparative clinical study of conventional dental implant and mini dental implant-retained mandibular overdenture: A 5- to 8-Year prospective clinical outcomes in a previous randomized clinical trial

Clin Implant Dent Relat Res. 2022 Aug;24(4):475-487. doi: 10.1111/cid.13098. Epub 2022 Jun 8.

Abstract

Aim: To compare the long-term prospective clinical outcomes in a previous randomized controlled clinical trial (RCT) of 2 Mini Dental Implant (2MDI), 4 Mini Dental Implant (4MDI), and 2 Conventional Dental Implant (2CDI)-retained mandibular overdenture with follow-up between 5 to 8 years.

Materials and methods: Thirty-seven patients formerly participated in the Comparative Clinical Study of CDI and MDI for Mandibular Overdenture were requested for examination of clinical outcomes. A total of 104 implants were placed with mean follow-up periods 6.64 ± 0.60 years. In Group 1 (2MDI) and Group 2 (4MDI), implants were placed and immediately loaded with Equator® attachments to retained mandibular overdenture. In Group 3 (2CDI), implants were placed and delayed 3 months for denture loading with ball attachment. The success rate, survival rate, clinical implant performance scale (CIP scale), peri-implant tissue status, prosthetic complication, implant stability quotient (ISQ), marginal bone level change (MBLC), and patient satisfactions were analyzed.

Results: After 5 to 8 years follow-up, the success rate in Groups 1, 2, and 3 were 90.91%, 93.33%, and 54.55%, respectively. The success rate in Group 3 was significantly lesser than Group 1 (p = 0.016) and Group 2 (p < 0.001). The survival rate in Groups 1, 2, and 3 was 100%, 96.67%, and 90.91%, respectively, and showed no significant differences. Mean ISQ reported no significant differences between groups. Mean MBLC were 0.57 ± 1.19 mm, 0.68 ± 0.90 mm, and 1.55 ± 1.60 mm in Groups 1, 2, and 3, respectively. Group 3 reported significantly greater mean MBLC than Group 1 (p = 0.016) and Group 2 (p = 0.011), but Groups 1 and 2 were not significantly differences. The overall patient satisfactions were reported as not significant differences between groups.

Conclude: Two MDI-retained mandibular overdentures with immediate loaded protocol performed had favorable clinical outcomes, cost effectiveness, and overall patient satisfactions after 5 to 8 years follow-up.

Keywords: ISQ; immediate loaded protocol; implant retained-mandibular overdenture; long-term clinical study; marginal bone level change; mini dental implant; patient satisfaction; success rate; survival rate.

MeSH terms

  • Dental Implants*
  • Dental Prosthesis, Implant-Supported
  • Denture Retention
  • Denture, Overlay
  • Follow-Up Studies
  • Humans
  • Jaw, Edentulous* / surgery
  • Mandible / surgery
  • Patient Satisfaction
  • Randomized Controlled Trials as Topic
  • Treatment Outcome

Substances

  • Dental Implants