Background: The reduction in irreducible extracapsular hip fractures has always been controversial. Here, we present a new minimally invasive reduction technique and compare it with limited open reduction (LOR) to treat irreducible extracapsular hip fractures.

Methods: From January 2016 to January 2018, our institution treated 653 patients with extracapsular hip fractures by intramedullary fixation. Among them, 525 cases got a successful closed reduction. The other 128 were irreducible and reduced by percutaneous reduction with double screwdrivers (PRDS) or LOR. There were 66 cases in the PRDS group while 62 in the LOR group. All fractures were classified using the Evans-Jensen classification. In addition, the differences in incision length, blood loss, fluoroscopic number, operation time, inpatient time, weight training time, Harris score, and complications were analyzed.

Results: The incision length was 8.4 ± 1.4 cm in the PRDS group and 15.3 ± 3.0 cm in the LOR group, respectively (p < 0.05); blood loss was equal to 151 ± 26 and 319 ± 33 ml, respectively (p < 0.05); fluoroscopic number was 14 ± 3 and 8 ± 2, respectively (p < 0.05); operation time was 44 ± 9 and 73 ± 11 min, respectively (p < 0.05); inpatient time was 6.2 ± 1.7 and 8.4 ± 2.2 days, respectively (p < 0.05); weight training time after the operation was 4.5 ± 1.5 and 10.7 ± 1.8 days, respectively (p < 0.05); and the excellent rate of Harris score was 92.4% and 88.7%, respectively (p > 0.05). There was no significant difference in complication incidence between the two groups (p > 0.05).

Conclusions: The PRDS group presented better clinical effects for managing irreducible extracapsular hip fractures than the LOR. Therefore, the PRDS technique could be the first reduction choice for patients with irreducible fractures.

Keywords: Extracapsular hip fracture; Irreducible; Percutaneous reduction; Screwdriver.

MeSH terms

  • Bone Nails
  • Fracture Fixation, Internal / adverse effects
  • Fracture Fixation, Intramedullary* / methods
  • Hip Fractures* / diagnostic imaging
  • Hip Fractures* / surgery
  • Humans
  • Retrospective Studies
  • Treatment Outcome