[Effect analysis of trajectory screw technique in fragility fracture of pelvic ring]

Zhongguo Gu Shang. 2022 Apr 25;35(4):309-16. doi: 10.12200/j.issn.1003-0034.2022.04.002.
[Article in Chinese]

Abstract

Objective: To assess the clinical efficacy of minimally invasive technology with trajectory screw fixation for fragility fractures of pelvic(FFP).

Methods: A retrospective case control study was performed to analyze the clinical data of 35 patients with FFP who were treated and followed up between January 2016 and December 2019. There were 12 males and 23 females, aged from 65 to 99 years with an average of(75.4±7.8) years old. There were 13 cases of type Ⅱb, 7 cases of type Ⅱc, 8 cases of type Ⅲa, 2 cases of type Ⅲb, 2 cases of type Ⅲc, 1 case of type Ⅳb, and 2 cases of type Ⅳc according to Rommens FFP comprehensive classification. All patients received the treatment of minimally invasive technology with trajectory screws fixation. According to the different methods of anterior pelvic ring fixation, FFP patients were divided into two groups:12 cases were fixed with the pedicle screw rod system in the anterior pelvic subcutaneous internal fixator (INFIX) group;23 cases were fixed with hollow screws of the pubic symphysis, superior ramus of pubis or acetabular anterior column in the screw group. The operation time, intraoperative blood loss, intraoperative fluoroscopy times, length of hospital stay, cost of internal fixation, pre- and post-operative visual analogue scale(VAS) were compared between the two groups. The fracture reduction quality was evaluated according to the Matta criteria, and the clinical function was evaluated by the Majeed functional scoring system respectively.

Results: All patients were followed up for 12 to 39(16.5±5.4) months after surgery. There was no statistically significant difference in the operation time, intraoperative blood loss, intraoperative fluoroscopy time, and length of hospital stay between the two groups(P>0.05). As for the cost of internal fixation, the cost of internal fixation in the screw group [2 914 (2 914, 4 371) yuan] was significantly lower than that of the INFIX group [6 205 (6 205, 6 205) yuan] (P<0.05). No significant difference was observed in the incidence of postoperative complications between the two groups (P>0.05). There was no significant difference in VAS assessment at admission, 1 week, and 3 months after surgery between the two groups(P>0.05). However, the VAS assessment at 1 week and 3 months after surgery of the two groups were significantly better than those at admission(P<0.05). There was no significant difference in the quality of fracture reduction after the operation and the efficacy evaluation at the last follow-up between the two groups(P>0.05).

Conclusion: For the treatment of fragility fractures, minimally invasive technology with trajectory screw fixation can achieve good clinical efficacy. It has the advantages of being relatively minimally invasive, less bleeding, relieving the pain. It deserves clinical application.

Keywords: Fracture fixation, internal; Fractures; Pelvis; Surgical procedures, minimal invasive.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Blood Loss, Surgical
  • Case-Control Studies
  • Female
  • Fractures, Bone* / surgery
  • Humans
  • Male
  • Pelvic Bones* / surgery
  • Retrospective Studies