[Determination of creatinine and 2-thiothiazolidine-4-carboxylic acid in urine by ultra high performance liquid chromatography tandem mass spectrometry]

Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi. 2022 Mar 20;40(3):226-230. doi: 10.3760/cma.j.cn121094-20210817-00399.
[Article in Chinese]

Abstract

Objective: To establish an ultrahigh performance liquid chromatography tandem mass spectrometry method for the determination of creatinine (Cre) and 2-thiothiazolidine-4-carboxylic acid (TTCA) in urine. Methods: In October 2020, the end-of-shift urine samples of the monitored subjects were taken, and the filtrate was prepared by centrifugation. After separated by ultra high performance liquid chromatography C18 column, acetonitrile and 0.2% acetic acid aqueous solution were used as mobile phases for gradient elution, the three quadrupole tandem mass spectrometry adopted an electrospray ion source (ESI) , the ion source temperature was 500 ℃ , and the air curtain gas flow rate was 31.4 L/min, qualitative and quantitative analysis of Cre and TTCA were carried out under the multiple reaction monitoring mode. Results: The linear range of Cre was 1.0-1 000.0 μg/L, the linear equation was y=947.3x-1605.6, and the correlation coefficient was 0.9994. The detection limit and the limit of quantitation were 0.3, 1.0 μg/L. When the addition concentrations were 50.0, 150.0 and 450.0 μg/L, the recovery rates were 92.8%-94.6% , the intra assay precisions were 3.6%-5.7% , and the inter assay precisions were 3.4%-5.4%. The linear range of TTCA was 0.1-200.0 μg/L, the linear equation was y=1164.7x-2243.9, and the correlation coefficient was 0.9991. The detection limit and the limit of quantitation were 0.03, 0.1 μg/L. When the addition concentrations were 10.0, 40.0 and 160.0 μg/L, the recovery rates were 90.8%-93.6%, the intra assay precisions were 4.6%-7.4%, and the inter assay precisions were 4.4%-6.9%. Conclusion: The sample pretreatment process of the ultra high performance liquid chromatography tandem mass spectrometry method for the determination of Cre and TTCA in urine is simple, and the continuous determination of Cre and TTCA in urine can be realized only by switching mass spectrometry parameters under the same chromatographic conditions, which is accurate and efficient, and each performance index of the method meets the determination requirements.

目的: 建立测定尿中肌酐(Cre)和2-硫代噻唑烷-4-羧酸(TTCA)的超高效液相色谱串联质谱法。 方法: 于2020年10月,取监测对象班末尿样,离心制备滤液,经超高效液相色谱仪C18色谱柱分离后,以乙腈和0.2%乙酸水溶液作流动相进行梯度淋洗;三重四极杆串联质谱采用电喷雾离子源(ESI),离子源温度500 ℃,气帘气流量31.4 L/min,在多反应监测模式下进行Cre和TTCA的定性、定量分析。 结果: Cre的线性范围为1.0~1 000.0 μg/L,线性方程为y=947.3x-1 605.6,相关系数0.999 4,检出限为0.3 μg/L,定量限为1.0 μg/L;当添加浓度为50.0、150.0、450.0 μg/L时,测得加标回收率为92.8%~ 94.6%,批内精密度为3.6%~5.7%,批间精密度为3.4%~5.4%。TTCA的线性范围为0.1~200.0 μg/L,线性方程为y=1 164.7x-2 243.9,相关系数0.999 1,检出限为0.03 μg/L,定量限为0.1 μg/L;当添加浓度为10.0、40.0、160.0 μg/L时,测得加标回收率为90.8%~93.6%,批内精密度为4.6%~7.4%,批间精密度为4.4%~6.9%。 结论: 尿中Cre和TTCA的超高效液相色谱串联质谱测定法样品前处理过程简单,在相同色谱条件仅通过切换质谱参数即可实现尿中Cre、TTCA的连续测定,准确高效,方法各性能指标均符合测定要求。.

Keywords: 2-thiothiazolidine-4-carboxylic acid; Carbon disulfide; Creatinine; Liquid chromatography tandem mass spectrometry; Urine.

MeSH terms

  • Chromatography, High Pressure Liquid
  • Creatinine
  • Humans
  • Tandem Mass Spectrometry*
  • Thiazolidines

Substances

  • Thiazolidines
  • 2-thioxo-4-thiazolidinecarboxylic acid
  • Creatinine