Impact of lipoprotein (a) on long-term outcome after percutaneous coronary intervention in the era of new generation drug-eluting stents

J Cardiol. 2022 Aug;80(2):179-183. doi: 10.1016/j.jjcc.2022.03.004. Epub 2022 Mar 28.

Abstract

Background: High lipoprotein (a) [Lp (a)] levels are associated with worse long-term outcomes in patients undergoing percutaneous coronary intervention (PCI). However, there are limited studies investigating association between Lp (a) levels and long-term outcomes in the era of new generation drug-eluting stents (DES).

Methods: A total of 495 patients with available data on Lp (a) who underwent PCI for de novo lesions with new generation DES were enrolled between 2013 and 2017. The primary endpoint was the major adverse cardiovascular event (MACE), which was defined as a composite of cardiac death, myocardial infarction, stent thrombosis, clinically driven target lesion revascularization, and revascularization for new lesions during 3 years. Patients were divided into 2 groups according to the Lp (a) level: high Lp (a) group (≥30 mg/dL: n = 109) and low Lp (a) group (30 mg/dL>: n = 386). Multivariate Cox regression analysis was performed to identify the predictors for 3-year MACE.

Results: The incidence of 3-year MACE was significantly higher in high Lp (a) group than low Lp (a) group (33.0% vs. 15.9%, p < 0.001). Multivariable analysis showed that Lp (a) level of ≥30 mg/dL was an independent predictor for 3-year MACE (HR 2.01, 95%CI 1.30-3.11, p = 0.002).

Conclusion: High Lp (a) level was associated with worse long-term outcome even in the era of new generation DES.

Keywords: Coronary artery disease; Lipoprotein (a); New generation drug-eluting stents.

MeSH terms

  • Coronary Artery Disease* / etiology
  • Drug-Eluting Stents*
  • Humans
  • Lipoprotein(a)
  • Percutaneous Coronary Intervention* / adverse effects
  • Prosthesis Design
  • Risk Factors
  • Treatment Outcome

Substances

  • Lipoprotein(a)