Mid-trimester uterine electromyography in patients with a short cervix

Am J Obstet Gynecol. 2022 Jul;227(1):83.e1-83.e17. doi: 10.1016/j.ajog.2022.03.046. Epub 2022 Mar 26.

Abstract

Background: Preterm birth is the largest single cause of infant death in the United States. A cervical length of <2.5 cm, measured in the mid-trimester, has been shown to identify individuals at increased risk. Uterine electromyography is an emerging technology for noninvasively assessing uterine bioelectrical activity. With its ability to characterize nuanced differences in myometrial signals, uterine electromyography assessments during the mid-trimester may provide insight into the mechanisms of cervical shortening.

Objective: This study aimed to characterize uterine bioelectrical activity in pregnant individuals with short cervices in the mid-trimester compared with that of pregnant individuals of the same gestational age with normal cervical lengths.

Study design: This is a prospective cohort study of subjects with singleton, nonanomalous pregnancies between 16 weeks and 0 days and 22 weeks and 6 days of gestational age. Subjects with normal cervical length (≥3.0 cm) were compared with subjects with short cervical length (<2.5 cm). The short-cervical-length cohort was further stratified by history of preterm birth. Multichannel uterine electromyography recordings were obtained for ∼60 minutes using proprietary, directional electromyography sensors on the abdomen. Uterine electromyography signals were observed and classified in groups as spikes, short bursts, and bursts. Primary outcomes were relative expression of spike, short-burst, and burst uterine electromyography signals. Subgroup analyses assessed each signal percentage by cervical length, history of preterm birth, and gestational age at delivery. Differences in percentage of uterine electromyography signals according to cervical length were analyzed using nonparametric tests of significance.

Results: Of the 28 included subjects, 10 had normal and 18 had short cervical length. There were 9 subjects with short cervical length and a history of preterm birth. Spikes were the most commonly recorded signals and were higher in the normal-cervical-length cohort (96.3% [interquartile range, 93.1%-100.0%]) than the short-cervical-length cohort (75.2% [interquartile range, 66.7%-92.0%], P=.001). In contrast, median percentages of short-bursts and bursts were significantly higher in subjects with a short cervical length (17.3% [interquartile range, 13.6%-23.9%] vs 2.5% for normal cervical length [interquartile range, 0%-5.5%], P=.001 and 6.6% [interquartile range, 0%-13.4%] vs 0% for normal cervical length [interquartile range, 0%-2.8%], P=.014, respectively). Within subgroup analyses, cervical length was inversely proportional to percentage of observed short-bursts (P=.013) and bursts (P=.014). Subjects with short cervical length and history of preterm birth had higher burst percentages (12.8% [interquartile range, 9.0%-15.7%]) than those with short cervical length and no history of preterm birth (3.3% [interquartile range, 0%-5.0%], P=.003).

Conclusion: Short-burst and burst uterine electromyography signals are observed more frequently in mid-trimester patients with short cervical lengths. This relationship provides insight into abnormal myometrial activation in the mid-trimester and offers a plausible biophysiological link to cervical shortening.

Keywords: abnormal myometrial activation; bioelectrical activity; bursts; cervical shortening; contractions; myometrial signaling; preterm birth; short-bursts; spikes; uterine signaling patterns.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Cervical Length Measurement
  • Cervix Uteri / diagnostic imaging
  • Electromyography / adverse effects
  • Female
  • Humans
  • Pregnancy
  • Pregnancy Trimester, Second
  • Premature Birth* / diagnosis
  • Premature Birth* / etiology
  • Prospective Studies
  • Uterine Cervical Incompetence*