Abstract

Given the application of αB-VxXXIVA-conotoxin (αB-CTX) in analgesics and cancer chemotherapeutics, and its threat to humans, it is urgent to develop a rapid, effective and accurate method for the analysis and detection of αB-CTX in real shellfish and medicine drug samples. In the present study, two different immunochromatographic strips were established for αB-CTX detection, based on the monoclonal antibody 5E4 against αB-CTX, and the visual limits of detection (vLOD) for the colloidal gold nanoparticles-based strip (AuNPs-based strip) and nanoflowers-based strip (AuNFs-based strip) were 4 μg/mL and 1.5 μg/mL, respectively. The developed AuNPs-/AuNFs-based strips have good specificity and accuracy, and the detection results were analyzed in less than 10 min, without using an instrument. In view of the excellent repeatability and usability, the established methods could be applied to detect and analyze the content of αB-CTX in real samples.

Keywords: AuNFs-based strip; AuNPs-based strip; detection; monoclonal antibody; αB-VxXXIVA-conotoxin.