Optimising tumour coverage and organ at risk sparing for hypofractionated re-irradiation in glioblastoma

Phys Imaging Radiat Oncol. 2022 Feb 24:21:84-89. doi: 10.1016/j.phro.2022.02.012. eCollection 2022 Jan.

Abstract

Background and purpose: Re-irradiation may be used for recurrent glioblastoma (GBM) patients. In some cases Planning Target Volume (PTV) under-coverage is necessary to meet organ at risk (OAR) constraints. This study aimed to develop a Volumetric Modulated Arc Therapy planning solution for GBM re-irradiation including a means of assessing if target coverage would be achievable and how much PTV 'cropping' would be required to meet OAR constraints, based on PTV volume and OAR proximity.

Materials and methods: For 10 PTVs, 360°, 180°, two coplanar 180° and 180° + non-coplanar 45° arc arrangements were compared using 35 Gy in 10 fractions. Using the preferred arrangement, dose fall-off was modelled to determine the separation required between PTV and OAR to ensure OAR dose constraints were met, with data presented graphically. To evaluate the graph as an aid to planning, seven cases with overlap were replanned in two treatment planning systems (TPSs).

Results: There were no significant dosimetric differences between arc arrangements. 180° was preferred due to shorter treatment times. The graph, which indicated if 95% PTV coverage would be achievable based on PTV volume and OAR proximity, was employed in seven cases to guide planning in two TPSs. Plans were deliverable.

Conclusions: Re-irradiation treatment planning can be challenging, especially when PTV under-coverage is necessary. 180° was considered optimal. To assist in the planning process, graphical guidance was produced to inform planners whether PTV under-coverage would be necessary and how much PTV 'cropping' would be required to meet constraints during optimisation.

Keywords: Dose fall-off; Glioblastoma; Re-irradiation; Recurrent glioblastoma; Target-organ at risk overlap.