Evaluation of unsupervised 30-second chair stand test performance assessed by wearable sensors to predict fall status in multiple sclerosis

Gait Posture. 2022 May:94:19-25. doi: 10.1016/j.gaitpost.2022.02.016. Epub 2022 Feb 23.

Abstract

Background: One in two people with multiple sclerosis (PwMS) will fall in a three-month period. Predicting which patients will fall remains a challenge for clinicians. Standardized functional assessments provide insight into balance deficits and fall risk but their use has been limited to supervised visits.

Research question: The study aim was to characterize unsupervised 30-second chair stand test (30CST) performance using accelerometer-derived metrics and assess its ability to classify fall status in PwMS compared to supervised 30CST.

Methods: Thirty-seven PwMS (21 fallers) performed instrumented supervised and unsupervised 30CSTs with a single wearable sensor on the thigh. In unsupervised conditions, participants performed bi-hourly 30CSTs and rated their balance confidence and fatigue over 48-hours. ROC analysis was used to classify fall status for 30CST performance.

Results: Non-fallers (p = 0.02) but not fallers (p = 0.23) differed in their average unsupervised 30CST performance (repetitions) compared to their supervised performance. The unsupervised maximum number of 30CST repetitions performed optimized ROC classification AUC (0.79), accuracy (78.4%) and specificity (90.0%) for fall status with an optimal cutoff of 17 repetitions.

Significance: Brief durations of instrumented unsupervised monitoring as an adjunct to routine clinical assessments could improve the ability for predicting fall risk and fluctuations in functional mobility in PwMS.

Keywords: Accelerometer; Chair stand test; Falls; Multiple sclerosis; Wearable.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Fatigue
  • Humans
  • Multiple Sclerosis* / diagnosis
  • Postural Balance
  • Wearable Electronic Devices*