Mapping and ablation of left atrial roof-dependent tachycardias using an ultra-high resolution mapping system

BMC Cardiovasc Disord. 2022 Feb 16;22(1):57. doi: 10.1186/s12872-022-02505-z.

Abstract

Background: Left atrial roof-dependent tachycardias (LARTs) are common macroreentrant atrial tachycardias (ATs). We sought to characterize clinical LARTs using an ultra-high resolution mapping system.

Methods: This study included 22 consecutive LARTs in 21 patients who underwent AT mapping/ablation using Rhythmia systems.

Results: Three, 13, 4, and 2 LART patients were cardiac intervention naïve (Group-A), post-roof line ablation (Group-B), post-atrial fibrillation ablation without linear ablation (Group-C), and post-cardiac surgery (Group-D), respectively. The mean AT cycle length was 244 ± 43 ms. Coronary sinus activation was proximal-to-distal or distal-to-proximal in 16 (72.7%) ATs. The activation map revealed 13 (59.1%) clockwise and 9 (40.9%) counter-clockwise LARTs. A 12-lead synchronous isoelectric interval was observed in 10/19 (52.6%) LARTs. The slow conduction area was identified on the LA roof, anterior/septal wall, and posterior wall in 18, 6, and 2 ATs, respectively. Twenty concomitant ATs among 13 procedures were also eliminated, and peri-mitral AT coexisted in 7 of 9 non-group-B patients. In group-B, the conduction gap was predominantly located on the mid-roof. Sustained LARTs were terminated by a single application and linear ablation in 6 (27.3%) and 9 (40.9%), while converting to other ATs in 7 (31.8%) LARTs. Complete linear block was created without any complications in all, however, ablation at the mid-posterior wall was required to achieve block in 4 (18.2%) procedures. During 14.0 (6.5-28.5) months of follow-up, 17 (81.0%) and 19 (90.5%) patients were free from any atrial tachyarrhythmias after single and last procedures.

Conclusions: The LART mechanisms were distinct in individual patients, and elimination of all concomitant ATs was required for the management.

Keywords: Atrial tachycardia; Catheter ablation; Roof line; Ultra-high resolution mapping.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Action Potentials*
  • Aged
  • Aged, 80 and over
  • Catheter Ablation* / adverse effects
  • Electrophysiologic Techniques, Cardiac / instrumentation*
  • Female
  • Heart Atria / physiopathology
  • Heart Atria / surgery*
  • Heart Rate
  • Humans
  • Male
  • Middle Aged
  • Predictive Value of Tests
  • Recurrence
  • Tachycardia, Supraventricular / diagnosis
  • Tachycardia, Supraventricular / physiopathology
  • Tachycardia, Supraventricular / surgery*
  • Time Factors
  • Treatment Outcome