Manganese(II) EOB-Pyclen Diacetate for Liver-Specific MRI

ACS Appl Bio Mater. 2022 Feb 21;5(2):451-458. doi: 10.1021/acsabm.1c01259. Epub 2022 Feb 11.

Abstract

MRI is increasingly utilized for the diagnosis of liver disease and focal liver lesions. Although liver-targeted gadolinium-based contrast agents (GBCAs) have high efficacy, there continue to be safety concerns regarding release of toxic Gd(III) ions. Herein, Mn(EOB-PC2A) is synthesized as a nongadolinium alternative for liver-specific MRI. Mn(EOB-PC2A) has an r1 relaxivity of 2.8 mM-1 s-1 in Dulbecco's phosphate-buffered saline (DPBS) and 5.9 mM-1 s-1 in saline containing human serum albumin at 1.5 T. It has a strong uptake in hepatocytes with minimal toxicity and demonstrated robust liver-specific enhancement at a dose of 60 μmol/kg. Mn(EOB-PC2A) is a promising liver-specific contrast agent for liver MRI.

Keywords: MRI; contrast agent; liver specific; manganese; molecular imaging.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Azabicyclo Compounds
  • Contrast Media
  • Gadolinium DTPA*
  • Humans
  • Ions
  • Liver / diagnostic imaging
  • Magnetic Resonance Imaging
  • Manganese*

Substances

  • Azabicyclo Compounds
  • Contrast Media
  • Ions
  • pyclen
  • Manganese