Analysis of purple urine bag syndrome by low vacuum scanning electron microscopy

Med Mol Morphol. 2022 Jun;55(2):123-130. doi: 10.1007/s00795-022-00313-0. Epub 2022 Feb 4.

Abstract

Purple urine bag syndrome (PUBS) is seen in the prolonged indwelling bladder catheters, and the mechanism of its onset was investigated using low vacuum scanning electron microscopy (LVSEM), which enables us to study the 3D structure of urinary sediments and urine bag walls. The urinary sediment and urine bags of 2 cases of PUBS were observed by LVSEM. The urine was brown turbid urine with a pH of 8.5, and magnesium phosphate stones and granules were observed in the urinary sediment together with Gram-positive and Gram-negative bacilli. Bacteria that moved by Brownian motion were observed with a dark-field microscope. LVSEM showed granular crystals around the bacilli, cocci, or mycelium that adhered to the walls of the bag. Granular crystals were dissolved in chloroform and presumed to be a mixture of the bacterial metabolites indigo blue and indirubin red. LVSEM also detected unusual tubular and honeycomb-like graphene in the urinary sediments, which were derived from the inner layer of the silicon elastomer-coated rubber catheter. LVSEM revealed purple crystals produced by bacteria or fungi attached to the urine bag that caused PUBS.

Keywords: Bladder catheter; Low vacuum scanning electron microscope; Purple urine bag; Urinary sediment.

MeSH terms

  • Catheters, Indwelling
  • Humans
  • Microscopy, Electron, Scanning
  • Syndrome
  • Urinary Catheterization
  • Urinary Tract Infections* / microbiology
  • Vacuum