Stopping Hospital Infections With Environmental Services (SHINE): A Cluster-randomized Trial of Intensive Monitoring Methods for Terminal Room Cleaning on Rates of Multidrug-resistant Organisms in the Intensive Care Unit

Clin Infect Dis. 2022 Sep 30;75(7):1217-1223. doi: 10.1093/cid/ciac070.

Abstract

Background: Multidrug-resistant organisms (MDROs) frequently contaminate hospital environments. We performed a multicenter, cluster-randomized, crossover trial of 2 methods for monitoring of terminal cleaning effectiveness.

Methods: Six intensive care units (ICUs) at 3 medical centers received both interventions sequentially, in randomized order. Ten surfaces were surveyed each in 5 rooms weekly, after terminal cleaning, with adenosine triphosphate (ATP) monitoring or an ultraviolet fluorescent marker (UV/F). Results were delivered to environmental services staff in real time with failing surfaces recleaned. We measured monthly rates of MDRO infection or colonization, including methicillin-resistant Staphylococcus aureus, Clostridioides difficile, vancomycin-resistant Enterococcus, and MDR gram-negative bacilli (MDR-GNB) during a 12-month baseline period and sequential 6-month intervention periods, separated by a 2-month washout. Primary analysis compared only the randomized intervention periods, whereas secondary analysis included the baseline.

Results: The ATP method was associated with a reduction in incidence rate of MDRO infection or colonization compared with the UV/F period (incidence rate ratio [IRR] 0.876; 95% confidence interval [CI], 0.807-0.951; P = .002). Including the baseline period, the ATP method was associated with reduced infection with MDROs (IRR 0.924; 95% CI, 0.855-0.998; P = .04), and MDR-GNB infection or colonization (IRR 0.856; 95% CI, 0.825-0.887; P < .001). The UV/F intervention was not associated with a statistically significant impact on these outcomes. Room turnaround time increased by a median of 1 minute with the ATP intervention and 4.5 minutes with UV/F compared with baseline.

Conclusions: Intensive monitoring of ICU terminal room cleaning with an ATP modality is associated with a reduction of MDRO infection and colonization.

Keywords: bacterial; cross infection/prevention & control; cross infection/transmission; disinfectants; drug resistance; intensive care units; multiple.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, N.I.H., Extramural
  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Adenosine Triphosphate
  • Cross Infection* / epidemiology
  • Cross Infection* / prevention & control
  • Drug Resistance, Multiple, Bacterial
  • Gram-Negative Bacteria
  • Humans
  • Intensive Care Units
  • Methicillin-Resistant Staphylococcus aureus*
  • Vancomycin
  • Vancomycin-Resistant Enterococci*

Substances

  • Vancomycin
  • Adenosine Triphosphate