Selective Enhancement of Swine Myocardium with a Novel Ultrasound Enhancing Agent During Transthoracic Echocardiography

J Cardiovasc Transl Res. 2022 Aug;15(4):722-729. doi: 10.1007/s12265-022-10207-2. Epub 2022 Jan 31.

Abstract

Ultrasound enhancing agents are approved to delineate the endocardial border and opacify the left ventricle cavity (LVC). We present a nested phase change agent (NPCA) designed to enable selective myocardial enhancement without enhancing the LVC by employing a dual-activation mechanism dependent on sufficient ultrasound intensity and the microenvironment of the myocardium. Swine received bolus injections of NPCA while echocardiograms were collected and processed to determine background-subtracted acoustic intensities (AI) in the LVC and septal myocardium. At mechanical index (MI) ≥ 0.8, the NPCA enhanced the myocardium selectively (p < 0.001) while the LVC remained at baseline AI. A 5-mL bolus of NPCA enhanced swine myocardium and enhancement persisted for > 5 min at 1.4 MI, while hemodynamics and EKG remained normal. Our findings demonstrate that the NPCA enhances swine myocardium selectively without enhancing the LVC. The NPCA could have utility for functional and structural echocardiographic studies with clinical ultrasound using standard settings.

Keywords: Myocardial contrast echocardiography; Myocardial perfusion imaging; Nested phase change agent; Selective myocardial enhancement; Ultrasound enhancing agent.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Contrast Media*
  • Echocardiography*
  • Heart Ventricles / diagnostic imaging
  • Myocardium
  • Swine

Substances

  • Contrast Media