The impact of face shields on the quality of gastrointestinal endoscopy during the COVID-19 pandemic

BMC Gastroenterol. 2022 Jan 29;22(1):38. doi: 10.1186/s12876-022-02114-2.

Abstract

Background: Coronavirus disease 2019 (COVID-19) has become a global pandemic, with healthcare workers at a high risk of exposure. During this pandemic, endoscopists must wear personal protective equipment (PPE), including face shields, to prevent COVID-19 transmission; however, few studies have reported the impact of face shields on the quality of gastrointestinal (GI) endoscopy. We aimed to determine whether the use of PPE, including face shields, affected the quality of GI endoscopy during the COVID-19 pandemic.

Methods: The medical records of patients who had undergone screening or surveillance colonoscopy and gastric endoscopic submucosal dissection (ESD) at Dong-A University Hospital between June 2020 and March 2021 were retrospectively reviewed. Endoscopists wore isolation gowns, disposable gloves, and KF94 masks from June 2020 to October 2020. From November 2020, endoscopists also wore face shields. We compared GI endoscopy quality indicators between the first five months (no face shields) and the second five months (with face shields). In the non-face shield and face shield groups, we calculated the overall adenoma detection rates (ADRs), polyp detection rate (PDR), sessile serrated lesion detection rate (SSLDR), advanced neoplasia detection rate (ANDR), complete resection rate (CRR), number of polyps and/or adenomas per colonoscopy, and gastric ESD procedure time.

Results: In total, 1359 study patients had undergone screening or surveillance colonoscopy (face shield group, n = 679; non-face shield group, n = 680). No statistically significant between-group differences were observed (PDR, 49.04 vs. 52.50%, p = 0.202; ADR, 38.59 vs. 38.97%, p = 0.884; SSPDR, 1.91 vs. 1.32%, p = 0.388; ANDR, 3.98 vs. 3.97%, p = 0.991, respectively). No difference was found in colonoscopy quality indicators between patients examined by experienced and trainee endoscopists with and without face shields. Of 144 study patients who had undergone gastric ESD for gastric neoplasms, there were 72 patients in each group. No statistically significant differences were found in the CRR (94.44 vs 93.05%, p = 1.000) and procedure times (19.22 ± 9.33 vs. 19.03 ± 11.49, p = 0.911).

Conclusions: Wearing face shields during the COVID-19 pandemic did not affect the quality indicators for GI endoscopy.

Keywords: Adenomatous polyps; COVID-19; Colonic polyps; Colonoscopy; Endoscopy.

MeSH terms

  • COVID-19*
  • Colonoscopy
  • Humans
  • Pandemics
  • Retrospective Studies
  • SARS-CoV-2