Use of a Single Wearable Sensor to Evaluate the Effects of Gait and Pelvis Asymmetries on the Components of the Timed Up and Go Test, in Persons with Unilateral Lower Limb Amputation

Sensors (Basel). 2021 Dec 24;22(1):95. doi: 10.3390/s22010095.

Abstract

The Timed Up and Go (TUG) test quantifies physical mobility by measuring the total performance time. In this study, we quantified the single TUG subcomponents and, for the first time, explored the effects of gait cycle and pelvis asymmetries on them. Transfemoral (TF) and transtibial (TT) amputees were compared with a control group. A single wearable inertial sensor, applied to the back, captured kinematic data from the body and pelvis during the 10-m walk test and the TUG test. From these data, two categories of symmetry indexes (SI) were computed: One SI captured the differences between the antero-posterior accelerations of the two sides during the gait cycle, while another set of SI quantified the symmetry over the three-dimensional pelvis motions. Moreover, the total time of the TUG test, the time of each subcomponent, and the velocity of the turning subcomponents were measured. Only the TF amputees showed significant reductions in each SI category when compared to the controls. During the TUG test, the TF group showed a longer duration and velocity reduction mainly over the turning subtasks. However, for all the amputees there were significant correlations between the level of asymmetries and the velocity during the turning tasks. Overall, gait cycle and pelvis asymmetries had a specific detrimental effect on the turning performance instead of on linear walking.

Keywords: kinematics; limb prosthesis; sensory–motor gait disorders; spatial–temporal analysis; symmetry index.

MeSH terms

  • Amputation, Surgical
  • Amputees*
  • Artificial Limbs*
  • Biomechanical Phenomena
  • Gait
  • Humans
  • Lower Extremity
  • Pelvis
  • Postural Balance
  • Time and Motion Studies
  • Walking
  • Wearable Electronic Devices*