High throughput method to determine the surface activity of antimicrobial polymeric materials

MethodsX. 2021 Nov 25:8:101593. doi: 10.1016/j.mex.2021.101593. eCollection 2021.

Abstract

Surface colonization by microorganisms, combined with the rise in antibiotic resistance, is the main cause of production failures in various industries. Self-sterilising materials are deemed the best prevention of surface colonization. However, current screening methods for these sterilising materials are laborious and time-consuming. The disk diffusion antimicrobial assay and the Japanese industrial standard method for antimicrobial activity on solid surfaces, JIS Z 2801, were compared to our modified solid surface antimicrobial assay in terms of detecting the activity of antibiotic-containing cellulose disks against four bacterial pathogens. Our novel assay circumvents the long incubation times by utilising the metabolic active dye, resazurin, to shorten the time in which antibacterial results are obtained to less than 4 h. This assay allows for increased screening to identify novel sterilising materials for combatting surface colonisation.•Disk diffusion assay could only detect the activity of small compounds that leached from the material over 20-24 h.•JIS Z 2801 was also able to detect the surface activity of non-polar compounds, thought to be inactive based on the disk diffusion results.•The resazurin solid surface antimicrobial assay could obtain the same results as the JIS Z 2801, within a shorter time and in a high-throughput 96-well plate setup.

Keywords: Antimicrobial surface screening; Disk diffusion assay; JIS Z 2801; Resazurin assay; Self-sterilising materials.