The clinical value of ultrasonic cardiac output monitor in very-low birth-weight and extremely-low-birth-weight infants undergoing PDA ligation

Early Hum Dev. 2022 Feb:165:105522. doi: 10.1016/j.earlhumdev.2021.105522. Epub 2021 Dec 7.

Abstract

Background: Cardiorespiratory instability occurs very often in very-low-birth-weight (VLBW) and extremely-low-birth-weight (ELBW) infants undergoing patent ductus arteriosus (PDA) ligation during the early postoperative period. This study aimed to investigate ultrasonic cardiac output monitor (USCOM) as a bedside tool by evaluating the hemodynamic changes in preterm infants following PDA ligation and assessing factors that may influence these changes.

Methods: This was a single-center prospective observational study at a third-level neonatal intensive care unit. A total of 33 infants, including 21 VLBW and 12 ELBW infants, were involved. Hemodynamic measurements were performed in these infants using a USCOM preoperatively as well as 0-1 h, 8-10 h, and 24 h postoperatively.

Results: The PDA ligation was associated with reductions of the left ventricular cardiac output (LVCO) (P < 0.001), cardiac index (P < 0.001), flow time corrected (FTC) (P < 0.001), Smith-Madigan inotropy index (SMII) (P < 0.001), oxygen delivery (DO2) (P < 0.001), and oxygen delivery index (DO2I) (P < 0.001) and an increase of the systemic vascular resistance index (SVRI) (P < 0.001) at 0-1 h, 8-10 h, and 24 h post-ligation compared with the respective preoperative values. Compared with the respective values at 0-1 h post-ligation, there was no significant difference in the CI, SMII, or FTC at 8-10 h and 24 h post-ligation. However, the SVRI decreased at 8-10 h and 24 h post-ligation. Moreover, the DO2I increased at 8-10 h and 24 h post-ligation, and the LVCO and DO2 increased at 24 h post-ligation.

Conclusion: Our study confirmed that the hemodynamic changes measured by the USCOM were similar to those measured by echocardiography in previous reports. Thus, USCOM is a useful and convenient bedside tool for assessing hemodynamic changes to guide the use of fluids, inotropic agents, and vasopressors and help modify the post-ligation course, and they may be a surrogate for repeated echocardiography during the early post-ligation period in preterm infants or a preliminary screening method.

Keywords: Extremely low-birth-weight infant; Hemodynamics; PDA ligation; Patent ductus arteriosus; Very-low-birth-weight infant.

Publication types

  • Observational Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Cardiac Output
  • Ductus Arteriosus, Patent* / diagnostic imaging
  • Ductus Arteriosus, Patent* / surgery
  • Humans
  • Infant
  • Infant, Extremely Low Birth Weight*
  • Infant, Newborn
  • Infant, Premature
  • Ligation / methods
  • Ultrasonics