Combining inter-observer variability, range and setup uncertainty in a variance-based sensitivity analysis for proton therapy

Phys Imaging Radiat Oncol. 2021 Dec 2:20:117-120. doi: 10.1016/j.phro.2021.11.005. eCollection 2021 Oct.

Abstract

Margin concepts in proton therapy aim to ensure full dose coverage of the clinical target volume (CTV) in presence of setup and range uncertainty. Due to inter-observer variability (IOV), the CTV itself is uncertain. We present a framework to evaluate the combined impact of IOV, setup and range uncertainty in a variance-based sensitivity analysis (SA). For ten patients with skull base meningioma, the mean calculation time to perform the SA including 1.6 × 104 dose recalculations was 59 min. For two patients in this dataset, IOV had a relevant impact on the estimated CTV D95% uncertainty.

Keywords: Inter-observer variability; Proton therapy; Range uncertainty; Sensitivity analysis; Setup uncertainty.