Diagnosis of liver cirrhosis with two-dimensional shear wave elastography in biliary atresia before Kasai portoenterostomy

Pediatr Surg Int. 2022 Feb;38(2):209-215. doi: 10.1007/s00383-021-05044-4. Epub 2021 Nov 30.

Abstract

Purpose: To evaluate the application value of two-dimensional shear wave elastography (2D-SWE) for non-invasive diagnosis of liver cirrhosis (LC) in patients with biliary atresia (BA) before Kasai portoenterostomy (KP), and the cutoff value of liver stiffness measurement (LSM) for diagnosing LC.

Methods: The clinical data of 51 patients with BA who were diagnosed via surgery and pathological results from May 2017 to December 2018 in the department of general surgery, Beijing Children's Hospital, Capital Medical University, were retrospectively analyzed. The liver tissue specimens obtained during KP were evaluated according to the METAVIR criteria. The LSM was obtained using the 2D-SWE technique before KP.

Results: There was a grade positive correlation between LSM and METAVIR staging, and the Spearman correlation coefficient was 0.432 (P = 0.002). The AUC for 2D-SWE diagnosing LC (METAVIR score S = 4) in patients with BA before KP was 0.843 (95% confidence interval 0.736 ~ 0.950). The best cutoff value was 16.05 kPa, and the corresponding sensitivity was 75.0%, specificity was 83.7%, positive predictive value (PPV) was 46.1%, negative predictive value (NPV) was 94.7%, and the accuracy was 82.4%.

Conclusion: 2D-SWE can be used to noninvasively diagnose LC in patients with BA before KP, and the cutoff value is 16.05 kPa.

Keywords: Biliary atresia; Diagnostic tests; Liver cirrhosis; Noninvasive diagnosis; Two-dimensional shear wave elastography.