Long-term outcomes of percutaneous left atrial appendage closure for the prevention of stroke in patients with atrial fibrillation: Asia-Pacific experience

J Formos Med Assoc. 2022 Aug;121(8):1442-1449. doi: 10.1016/j.jfma.2021.10.010. Epub 2021 Nov 16.

Abstract

Background/purpose: In patients with non-valvular atrial fibrillation (NVAF), the left atrial appendage occluder (LAAO) is an alternative treatment for stroke prevention. However, the long-term outcomes in Asia was generally unknown.

Methods and results: This was a retrospective longitudinal study and a total of 124 patients with contraindications to oral anticoagulants or stroke despite under anticoagulants had been enrolled since 2013. Primary efficacy was defined as any type of stroke/systemic embolization and adverse event as any procedure or anti-thrombotic related complications. Twelve patients were excluded due to thrombus in the LAA or oversize LAA. Watchman was successfully implanted in 55 patients (98%) and ACP/Amulet also 55 patients (98%). During follow-up, the ischemic stroke rate was 1.9 in the Watchman and 1.4 per 100 patient-year in the ACP/Amulet group. There were 2 Watchman patients experiencing intracranial hemorrhage. Device-related thrombus (DRT) was noted in 3 patients (2.7%).There was no patient with peri-device lead ≧5 mm. In those patients receiving only local anesthesia, the follow-up echocardiography showed no significant peri-device leak, malposition of LAAO and DRT.

Conclusion: This long-term follow-up study shows that percutaneous closure of LAA is a safe and technically feasible procedure with satisfactory outcomes in Asia. The procedure success rate, efficacy and adverse event were similar to those reported in the Caucasian populations.

Keywords: Amplatzer cardiac plug; Amulet; Asia; Left atrial appendage occluder; Watchman.

MeSH terms

  • Anticoagulants / therapeutic use
  • Atrial Appendage* / diagnostic imaging
  • Atrial Appendage* / surgery
  • Atrial Fibrillation* / complications
  • Atrial Fibrillation* / surgery
  • Cardiac Catheterization / adverse effects
  • Cardiac Catheterization / methods
  • Follow-Up Studies
  • Humans
  • Longitudinal Studies
  • Retrospective Studies
  • Septal Occluder Device* / adverse effects
  • Stroke* / etiology
  • Stroke* / prevention & control
  • Thrombosis*
  • Treatment Outcome

Substances

  • Anticoagulants