Local Chemical Environment Governs Anode Processes in CO2 Electrolyzers

ACS Energy Lett. 2021 Nov 12;6(11):3801-3808. doi: 10.1021/acsenergylett.1c01937. Epub 2021 Oct 7.

Abstract

A major goal within the CO2 electrolysis community is to replace the generally used Ir anode catalyst with a more abundant material, which is stable and active for water oxidation under process conditions. Ni is widely applied in alkaline water electrolysis, and it has been considered as a potential anode catalyst in CO2 electrolysis. Here we compare the operation of electrolyzer cells with Ir and Ni anodes and demonstrate that, while Ir is stable under process conditions, the degradation of Ni leads to a rapid cell failure. This is caused by two parallel mechanisms: (i) a pH decrease of the anolyte to a near neutral value and (ii) the local chemical environment developing at the anode (i.e., high carbonate concentration). The latter is detrimental for zero-gap electrolyzer cells only, but the first mechanism is universal, occurring in any kind of CO2 electrolyzer after prolonged operation with recirculated anolyte.