Predictors for the risk of permanent pacemaker implantation after transcatheter aortic valve replacement: A systematic review and meta-analysis

J Card Surg. 2022 Feb;37(2):377-405. doi: 10.1111/jocs.16129. Epub 2021 Nov 14.

Abstract

Background: Transcatheter aortic valve replacement (TAVR) is a less invasive treatment than surgery for severe aortic stenosis. However, its use is restricted by the fact that many patients eventually require permanent pacemaker implantation (PPMI). This meta-analysis was performed to identify predictors of post-TAVR PPMI.

Methods: The PubMed, Embase, Web of Science, and Cochrane Library databases were systematically searched. Relevant studies that met the inclusion criteria were included in the pooling analysis after quality assessment.

Results: After pooling 67 studies on post-TAVR PPMI risk in 97,294 patients, balloon-expandable valve use was negatively correlated with PPMI risk compared with self-expandable valve (SEV) use (odds ratio [OR]: 0.44, 95% confidence interval [CI]: 0.37-0.53). Meta-regression analysis revealed that history of coronary artery bypass grafting and higher Society of Thoracic Surgeons (STS) risk score increased the risk of PPMI with SEV utilization. Patients with pre-existing cardiac conduction abnormalities in 28 pooled studies also had a higher risk of PPMI (OR: 2.33, 95% CI: 1.90-2.86). Right bundle branch block (OR: 5.2, 95% CI: 4.37-6.18) and first-degree atrioventricular block (OR: 1.97, 95% CI: 1.38-2.79) also increased PPMI risk. Although the trans-femoral approach was positively correlated with PPMI risk, the trans-apical pathway showed no statistical difference to the trans-femoral pathway. The approach did not increase PPMI risk in patients with STS scores >8. Patient-prosthesis mismatch did not influence post-TAVR PPMI risk (OR: 0.88, 95% CI: 0.67-1.16). We also analyzed implantation depth and found no difference between patients with PPMI after TAVR and those without.

Conclusions: SEV selection, pre-existing cardiac conduction abnormality, and trans-femoral pathway selection are positively correlated with PPMI after TAVR. Pre-existing left bundle branch block, patient-prosthesis mismatch, and implantation depth did not affect the risk of PPMI after TAVR.

Keywords: cardiac conduction abnormal; patient-prosthesis mismatch; surgical approach; valve implantation depth; valve selection.

Publication types

  • Meta-Analysis
  • Review
  • Systematic Review

MeSH terms

  • Aortic Valve / surgery
  • Aortic Valve Stenosis* / surgery
  • Heart Valve Prosthesis*
  • Humans
  • Pacemaker, Artificial*
  • Risk Factors
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Treatment Outcome