Reliability of pediatric ventricular function analysis by short-axis "single-cycle-stack-advance" single-shot compressed-sensing cines in minimal breath-hold time

Eur Radiol. 2022 Apr;32(4):2581-2593. doi: 10.1007/s00330-021-08335-5. Epub 2021 Oct 29.

Abstract

Objectives: Cardiovascular magnetic resonance (CMR) cine imaging by compressed sensing (CS) is promising for patients unable to tolerate long breath-holding. However, the need for a steady-state free-precession (SSFP) preparation cardiac cycle for each slice extends the breath-hold duration (e.g. for 10 slices, 20 cardiac cycles) to an impractical length. We investigated a method reducing breath-hold duration by half and assessed its reliability for biventricular volume analysis in a pediatric population.

Methods: Fifty-five consecutive pediatric patients (median age 12 years, range 7-17) referred for assessment of congenital heart disease or cardiomyopathy were included. Conventional multiple breath-hold SSFP short-axis (SAX) stack cines served as the reference. Real-time CS SSFP cines were applied without the steady-state preparation cycle preceding each SAX cine slice, accepting the limitation of omitting late diastole. The total acquisition time was 1 RR interval/slice. Volumetric analysis was performed for conventional and "single-cycle-stack-advance" (SCSA) cine stacks.

Results: Bland-Altman analyses [bias (limits of agreement)] showed good agreement in left ventricular (LV) end-diastolic volume (EDV) [3.6 mL (- 5.8, 12.9)], LV end-systolic volume (ESV) [1.3 mL (- 6.0, 8.6)], LV ejection fraction (EF) [0.1% (- 4.9, 5.1)], right ventricular (RV) EDV [3.5 mL (- 3.34, 10.0)], RV ESV [- 0.23 mL (- 7.4, 6.9)], and RV EF [1.70%, (- 3.7, 7.1)] with a trend toward underestimating LV and RV EDVs with the SCSA method. Image quality was comparable for both methods (p = 0.37).

Conclusions: LV and RV volumetric parameters agreed well between the SCSA and the conventional sequences. The SCSA method halves the breath-hold duration of the commercially available CS sequence and is a reliable alternative for volumetric analysis in a pediatric population.

Key points: • Compressed sensing is a promising accelerated cardiovascular magnetic resonance imaging technique. • We omitted the steady-state preparation cardiac cycle preceding each cine slice in compressed sensing and achieved an acquisition speed of 1 RR interval/slice. • This modification called "single-cycle-stack-advance" enabled the acquisition of an entire short-axis cine stack in a single short breath hold. • When tested in a pediatric patient group, the left and right ventricular volumetric parameters agreed well between the "single-cycle-stack-advance" and the conventional sequences.

Keywords: Diagnostic imaging; Multiparametric magnetic resonance imaging; Pediatric; Ventricular function.

MeSH terms

  • Adolescent
  • Breath Holding*
  • Child
  • Humans
  • Image Interpretation, Computer-Assisted / methods
  • Magnetic Resonance Imaging, Cine* / methods
  • Reproducibility of Results
  • Stroke Volume
  • Ventricular Function, Left