SARS-CoV-2 Serology Testing in an Asymptomatic, At-Risk Population: Methods, Results, Pitfalls

Infect Dis Rep. 2021 Oct 21;13(4):910-916. doi: 10.3390/idr13040082.

Abstract

The primary aim of this study was to determine the seroprevalence of SARS-CoV-2 antibodies in a population of pediatric healthcare workers (HCWs). This study was conducted 14 May-13 July 2020. Study participants included pediatric HCWs at a pediatric hospital with either direct patient contact or close proximity to patient-care areas. SARS-CoV-2 antibodies were assessed via the Wytcote Superbio SARS-CoV-2 IgM/IgG Antibody Fast Detection Kit and the Abbott Architect SARS-CoV-2 IgG assay. Participants underwent RT-PCR testing upon entry to the study and following rapid IgM+/IgG+ results; respiratory panel PCR (RP-PCR) was performed following IgM+ results. A total of 57 of 289 (19.7%) of participants demonstrated positive serology as assessed by the Wytcote rapid kit (12 on Day 1 and 45 throughout the study). However, only one of these participants demonstrated IgG+ serology via the Abbott assay. Two participants tested SARS-CoV-2+ via RT-PCR testing. One individual was adenovirus+ and enterovirus/rhinovirus+. In our study population, we observed a seroprevalence of SARS-CoV-2 antibodies of 0.35%. The lack of concordance between antibody tests suggests that the Wytcote rapid test kit may not be of use as a screening tool. However, the feasibility of the overall process indicates that a similar methodology may have potential for future epidemiologic surveillance.

Keywords: COVID-19; SARS-CoV-2; antibody testing; pediatric healthcare workers.