Operational Parameters for Sub-Nano Tesla Field Resolution of PHMR Sensors in Harsh Environments

Sensors (Basel). 2021 Oct 18;21(20):6891. doi: 10.3390/s21206891.

Abstract

The resolution of planar-Hall magnetoresistive (PHMR) sensors was investigated in the frequency range from 0.5 Hz to 200 Hz in terms of its sensitivity, average noise level, and detectivity. Analysis of the sensor sensitivity and voltage noise response was performed by varying operational parameters such as sensor geometrical architectures, sensor configurations, sensing currents, and temperature. All the measurements of PHMR sensors were carried out under both constant current (CC) and constant voltage (CV) modes. In the present study, Barkhausen noise was revealed in 1/f noise component and found less significant in the PHMR sensor configuration. Under measured noise spectral density at optimized conditions, the best magnetic field detectivity was achieved better than 550 pT/√Hz at 100 Hz and close to 1.1 nT/√Hz at 10 Hz for a tri-layer multi-ring PHMR sensor in an unshielded environment. Furthermore, the promising feasibility and possible routes for further improvement of the sensor resolution are discussed.

Keywords: field detectivity; magnetoresistive sensors; planar-Hall magnetoresistance; sensitivity.

MeSH terms

  • Electricity*
  • Magnetic Fields*