Abstract

Static automated perimetry is an indispensable tool in the diagnosis of glaucoma. It is used to study the differential light sensitivity of the retina in different points of the visual field. The most important is the central zone of the visual field, many perimetric programs and strategies have been developed for its examination. Using standard background brightness, we can vary sizes, location methods and the type of stimulus delivery. The proper use of standard achromatic perimetry is crucial for the correct management of glaucoma patients. This review analyzes literature on the basic principles of static perimetry in the examination of differential photosensitivity of the retina.

Статическая периметрия в настоящее время является незаменимой методикой в диагностике глаукомы. Ее используют для исследования дифференциальной световой чувствительности сетчатки в различных точках поля зрения. Наиболее важной является центральная зона поля зрения, для тестирования которой разработано множество периметрических программ и стратегий. При стандартной яркости фона они различаются размерами, способами расположения и характером подачи стимулов. Правильное использование стандартной, ахроматической, периметрии крайне важно для корректного ведения пациентов с глаукомой. В обзоре проанализированы данные литературы о базовых принципах статической периметрии в исследовании дифференциальной светочувствительности сетчатки.

Keywords: Humphrey Field Analyzer; Octopus; SITA; central visual field; glaucoma; static automated perimetry.

Publication types

  • Review

MeSH terms

  • Glaucoma* / diagnosis
  • Humans
  • Retina / diagnostic imaging
  • Visual Field Tests*
  • Visual Fields