An eco-friendly solvent-free reaction based on peptide probes: design an extraction-free method for analysis of acrylamide under microliter volume

Anal Bioanal Chem. 2021 Dec;413(30):7531-7539. doi: 10.1007/s00216-021-03717-6. Epub 2021 Oct 11.

Abstract

Acrylamide is a group 2A carcinogen and potential endocrine disruptor that can enter the ecosystem by various routes and has recently become a dangerous pollutant. This widely used chemical can enter the human body via air inhalation, food or water consumption, or skin contact. In this study, we developed a peptide probe for the detection of acrylamide by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) after its micro-tagging with a peptide. Direct detection of acrylamide by MALDI-TOF MS is not feasible due to its poor ionization in the MALDI interface, which hinders its analysis by the technique. After microwave irradiation for 2 min, the formed acrylamide-peptide derivative was detected easily by MALDI-TOF MS without the need for extraction procedures. The procedure does not involve organic solvents and a water-soluble peptide that allows detection of acrylamide in small sample volumes with a limit of detection (LOD) of 0.05 ng/μL. The relative standard deviation (RSD) and relative error (RE) of the measurements were < 6.7% for intra- and inter-day assays. Gel-washing solutions from a polyacrylamide gel experiment were used as a model to study the efficiency of the developed method. Finally, we used the proposed method for the detection of free acrylamide in small volumes of lung epithelial cells (a model to test the air inhalation of acrylamide under a tiny volume of sample) and human urine. The developed method will enable rapid acrylamide detection in environmental and biological samples via a green approach based on microwave-assisted derivatization in water alongside the use of a less toxic derivatization reagent, reusable target plate, and miniaturization protocols.

Keywords: Acrylamide; MALDI-TOF MS; Organic solvent free; Peptide probes.

MeSH terms

  • Acrylamide / analysis*
  • Acrylamide / urine
  • Animals
  • Cell Line
  • Epithelial Cells / chemistry
  • Humans
  • Limit of Detection
  • Lung / chemistry
  • Lung / cytology
  • Mice
  • Molecular Probes / chemistry*
  • Peptides / chemistry*
  • Reproducibility of Results
  • Solvents / chemistry
  • Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization / methods

Substances

  • Molecular Probes
  • Peptides
  • Solvents
  • Acrylamide