Effect of gamma irradiation on filtering facepiece respirators and SARS-CoV-2 detection

Sci Rep. 2021 Oct 6;11(1):19888. doi: 10.1038/s41598-021-99414-6.

Abstract

To cope with the shortage of filtering facepiece respirators (FFRs) during the coronavirus (COVID-19) pandemic, healthcare institutions were forced to reuse FFRs after applying different decontamination methods including gamma-irradiation (GIR). The aim of this study was to evaluate the effect of GIR on the filtration efficiency (FE) of FFRs and on SARS-CoV-2 detection. The FE of 2 FFRs types (KN95 and N95-3 M masks) was assessed at different particle sizes (0.3-5 µm) following GIR (0-15 kGy) delivered at either typical (1.65 kGy/h) or low (0.5088 kGy/h) dose rates. The detection of two SARS-CoV-2 RNA genes (E and RdRp4) following GIR (0-50 kGy) was carried out using RT-qPCR assay. Both masks showed an overall significant (P < 0.001) reduction in FE with increased GIR doses. No significant differences were observed between GIR dose rates on FE. The GIR exhibited significant increases (P ≤ 0.001) in the cycle threshold values (ΔCt) of both genes, with no detection following high doses. In conclusion, complete degradation of SARS-CoV-2 RNA can be achieved by high GIR (≥ 30 kGy), suggesting its potential use in FFRs decontamination. However, GIR exhibited adverse effects on FE in dose- and particle size-dependent manners, rendering its use to decontaminate FFRs debatable.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • COVID-19 / prevention & control
  • COVID-19 / transmission
  • COVID-19 / virology*
  • Decontamination / methods*
  • Filtration
  • Gamma Rays
  • Humans
  • Masks*
  • Particle Size
  • SARS-CoV-2 / isolation & purification*
  • Ventilators, Mechanical*