Full thickness quadriceps tendon grafts with bone had similar material properties to bone-patellar tendon-bone and a four-strand semitendinosus grafts: a biomechanical study

Knee Surg Sports Traumatol Arthrosc. 2022 May;30(5):1786-1794. doi: 10.1007/s00167-021-06738-x. Epub 2021 Sep 30.

Abstract

Purpose: Despite increasing interest in utilizing quadriceps tendon (QT) grafts in anterior cruciate ligament reconstruction (ACLR), data on the optimal quadriceps graft thickness are limited. The purpose of this study was to characterize the mechanical properties for the quadriceps tendon, comparing full-thickness (FT) QT grafts with and without bone to a partial-thickness (PT) QT graft, and comparing the three QT grafts to four-stranded semitendinosus (4-SST) and bone-patellar tendon-bone (BTB) grafts and one experimental graft, the two-stranded rectus femoris (RF).

Methods: Forty-eight (n = 48) young cadaveric grafts (mean age 32 ± 6 years) were utilized for testing with N = 8 specimens in each of the following groups; (1) FT QT with bone, (2) FT QT without bone, (3) PT QT without bone, (4) BTB, (5) RF, and (6) 4-SST. Each specimen was harvested and rigidly fixed in custom clamps to a dynamic tensile testing machine for biomechanical evaluation. Graft ultimate load and stiffness were recorded. Independent groups one-factor ANOVAs and Tukey's pairwise comparisons were performed for statistical analyses.

Results: FT QT with bone and 4-SST grafts demonstrated similar ultimate loads to BTB grafts (both n.s), whereas PT QT demonstrate statistically significantly lower ultimate loads to BTB grafts (n.s) and 4-SST grafts (n.s). Furthermore, no statistically significant differences were observed between the ultimate loads of FT QT vs. PT QT grafts without bone (n.s) or between FT QT with vs. without bone (n.s). FT QT grafts with bone did not demonstrate statistically significantly greater ultimate loads than PT QT grafts without bone (n.s). The RF graft demonstrated statistically significantly lower ultimate loads to BTB grafts (p < 0.005) and 4-SST grafts (p < 0.014).

Conclusions: Full thickness QT grafts with bone had similar material properties to BTB and a 4-SST grafts, while Partial thickness QT graft without bone had significantly lower material properties than BTB and 4-SST, in a biomechanical setting.

Keywords: ACL; ACL reconstruction; Biomechanics; Bone-patellar tendon-bone; Hamstring tendon; Knee ligament; Quadriceps tendon.

MeSH terms

  • Adult
  • Anterior Cruciate Ligament Injuries* / surgery
  • Anterior Cruciate Ligament Reconstruction*
  • Hamstring Muscles* / surgery
  • Humans
  • Patellar Ligament* / surgery
  • Quadriceps Muscle / surgery
  • Tendons / transplantation