LI-RADS Tumor in Vein at CT and Hepatobiliary MRI

Radiology. 2022 Jan;302(1):107-115. doi: 10.1148/radiol.2021210215. Epub 2021 Sep 28.

Abstract

Background Diagnostic performance of the Liver Imaging Reporting and Data System tumor in vein (LR-TIV) category at CT and/or MRI has not yet been evaluated, to the knowledge of the authors. Purpose To assess the diagnostic performance of the LR-TIV category in detecting macroscopic tumors in veins (TIVs) at CT and hepatobiliary contrast agent-enhanced (HBA) MRI, with pathologic results used as the reference standard. Materials and Methods Between January 2010 and December 2019, consecutive patients with or without macroscopic TIV who underwent both CT and HBA MRI before hepatic resection or liver transplant were retrospectively included. Three radiologists independently assessed the LR-TIV features of enhancing soft tissue in vein and features suggestive of TIV (FSTIV) and reached a consensus. Macroscopic TIV at pathologic examination was the reference standard. Sensitivities and specificities of the LR-TIV category without and with FSTIV were calculated, and the added value of FSTIV was evaluated by using the McNemar test. Results In the 1322 patients with (n = 101) or without (n = 1221) macroscopic TIV (median age, 64 years [interquartile range, 58-70 years]; 1053 men), without consideration of FSTIV, the sensitivity and specificity of enhancing soft tissue in vein for detecting macroscopic TIV at pathologic examination were 64.4% (65 of 101) and 99.8% (1218 of 1221) with CT and 62.4% (63 of 101) and 99.8% (1218 of 1221) with HBA MRI, respectively. With consideration of FSTIV, the sensitivity and specificity of the LR-TIV category became 67.3% (68 of 101 patients) and 99.7% (1217 of 1221 patients) at both CT and HBA MRI. No difference was found between measurements without and with FSTIV (sensitivity, 62% vs 67% for CT [P = .45] and 64% vs 67% for HBA MRI [P = .18]; specificity, 99% for both CT and HBA MRI [P > .99 for both]). Conclusion The Liver Imaging Reporting and Data System tumor in vein category showed moderate sensitivity and high specificity in the detection of macroscopic tumors in veins at both CT and hepatobiliary contrast agent-enhanced MRI, with pathologic examination used as the reference standard. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Morrell in this issue.

MeSH terms

  • Aged
  • Contrast Media
  • Female
  • Humans
  • Image Enhancement / methods
  • Liver / blood supply
  • Liver / diagnostic imaging
  • Liver Neoplasms / diagnostic imaging*
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Radiology Information Systems*
  • Reproducibility of Results
  • Retrospective Studies
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods*
  • Vascular Neoplasms / diagnostic imaging*

Substances

  • Contrast Media