Diagnostic Accuracy of FEC-PET/CT, FDG-PET/CT, and Diffusion-Weighted MRI in Detection of Nodal Metastases in Surgically Treated Endometrial and Cervical Carcinoma

Clin Cancer Res. 2021 Dec 1;27(23):6457-6466. doi: 10.1158/1078-0432.CCR-21-1834. Epub 2021 Sep 15.

Abstract

Purpose: Preoperative nodal staging is important for planning treatment in cervical cancer and endometrial cancer, but remains challenging. We compare nodal staging accuracy of 18F-ethyl-choline-(FEC)-PET/CT, 18F-fluoro-deoxy-glucose-(FDG)-PET/CT, and diffusion-weighted-MRI (DW-MRI) with conventional morphologic MRI.

Experimental design: A prospective, multicenter observational study of diagnostic accuracy for nodal metastases was undertaken in 5 gyne-oncology centers. FEC-PET/CT, FDG-PET/CT, and DW-MRI were compared with nodal size and morphology on MRI. Reference standard was strictly correlated nodal histology. Eligibility included operable cervical cancer stage ≥ 1B1 or endometrial cancer (grade 3 any stage with myometrial invasion or grade 1-2 stage ≥ II).

Results: Among 162 consenting participants, 136 underwent study DW-MRI and FDG-PET/CT and 60 underwent FEC-PET/CT. In 118 patients, 267 nodal regions were strictly correlated at histology (nodal positivity rate, 25%). Sensitivity per patient (n = 118) for nodal size, morphology, DW-MRI, FDG- and FEC-PET/CT was 40%*, 53%, 53%, 63%*, and 67% for all cases (*, P = 0.016); 10%, 10%, 20%, 30%, and 25% in cervical cancer (n = 40); 65%, 75%, 70%, 80% and 88% in endometrial cancer (n = 78). FDG-PET/CT outperformed nodal size (P = 0.006) and size ratio (P = 0.04) for per-region sensitivity. False positive rates were all <10%.

Conclusions: All imaging techniques had low sensitivity for detection of nodal metastases and cannot replace surgical nodal staging. The performance of FEC-PET/CT was not statistically different from other techniques that are more widely available. FDG-PET/CT had higher sensitivity than size in detecting nodal metastases. False positive rates were low across all methods. The low false positive rate demonstrated by FDG-PET/CT may be helpful in arbitration of challenging surgical planning decisions.

Publication types

  • Multicenter Study
  • Observational Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Diffusion Magnetic Resonance Imaging
  • Female
  • Fluorodeoxyglucose F18
  • Humans
  • Magnetic Resonance Imaging / methods
  • Neoplasm Staging
  • Positron Emission Tomography Computed Tomography*
  • Positron-Emission Tomography / methods
  • Prospective Studies
  • Radiopharmaceuticals
  • Tomography, X-Ray Computed / methods
  • Uterine Cervical Neoplasms* / diagnostic imaging
  • Uterine Cervical Neoplasms* / surgery

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18