Purpose: The purpose of the study is to evaluate the initial and midterm efficacy and safety of endovascular treatment (EVT) using Viabahn stent-graft (SG) for arterial injury and bleeding (AIB) at the visceral arteries.
Materials and methods: Consecutive patients with visceral AIB who underwent EVT using Viabahn between January 2017 and February 2021 were retrospectively reviewed. Technical success, clinical success, peripheral organ ischemia, peri-procedural complications, bleeding-related mortality, 30-day mortality, neck length, re-bleeding, endoleaks, and patency of the SGs at 1, 3, 6, and 12 months were evaluated.
Results: EVT using Viabahn was performed in 14 patients (mean age: 68.6 years; 12 males) and 15 arteries. The technical and clinical success rates were 100%. The rates of peripheral organ ischemia, peri-procedural complications, bleeding-related mortality, and 30-day mortality were all 0%. The mean neck length was 9.9 mm. No endoleaks or re-bleeding occurred during the follow-up (mean: 732 days). The SG patency was confirmed after 1, 3, 6, and 12 months in 78.6%, 78.6%, 78.6%, and 56.1% of the patients, respectively.
Conclusion: EVT using Viabahn for AIB at the visceral arteries was safe and effective. SG occlusions without ischemia often occurred after 12 months.
Keywords: Arterial bleeding; Arterial injury; Viabahn stent-graft; Visceral artery.
© 2021. The Author(s).