Experimental Study on Thermal Runaway Process of 18650 Lithium-Ion Battery under Different Discharge Currents

Materials (Basel). 2021 Aug 22;14(16):4740. doi: 10.3390/ma14164740.

Abstract

Lithium-ion batteries (LIBs) subjected to external heat may be prone to failure and cause catastrophic safety issues. In this work, experiments were conducted to investigate the influence of discharge current on the thermal runaway process under thermal abuse. The calibrated external heat source (20 W) and discharge currents from 1 to 6 A were employed to match the thermal abuse conditions in an operational state. The results indicated that the key parameters during the failure process, such as the total mass loss, the onset temperatures of safety venting and thermal runaway, and the peak temperature, are ultimately determined by the capacity inside the battery, and the discharge current can hardly change it. However, discharge currents can produce extra energy to accelerate the thermal runaway process. Compared with the battery in an open circuit, the onset time of thermal runaway was reduced by 7.4% at 6 A discharge. To quantify the effect of discharge current, the total heat generation by discharge current was calculated. The results show that a heat generation of 1.6 kJ was produced when the battery was discharged at 6 A, which could heat the cell to 34 °C (neglect of heat loss). This study simulates the failure process of the LIB in the operational state, which is expected to help the safety application of LIB and improve the reliability of the battery management system.

Keywords: discharge condition; heat generation; lithium-ion batteries; operational state; thermal runaway.