Nonindicated Brain Computed Tomography Scans for Children: Adaptation of an American Measurement Tool and Contrast of Current Practice in an Australian Hospital

Pediatr Emerg Care. 2022 Feb 1;38(2):e550-e555. doi: 10.1097/PEC.0000000000002515.

Abstract

Objectives: Clinical guidelines state brain computed tomography (CT) for atraumatic headache or first generalized afebrile, atraumatic seizure as nonindicated in neurologically normal children. We aimed to adapt 2 rigorously validated United States-based measures that examine overuse of CT in children with these conditions, and to determine whether these measures can be used in an Australian setting to determine rates of CT scanning in current practice.

Methods: Within an Australian tertiary pediatric hospital, we successfully adapted the measures from the International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) coding system of the United States measures to the International Classification of Diseases, Tenth Revision, Australian Modification (ICD-10-AM) coding system used in Australia. We conducted a retrospective audit of electronic medical record data from April 1, 2017, to March 31, 2018. Eligible patients were children aged 4 to 17 years who attended one of the hospital outpatient clinics and/or emergency department and/or were admitted to an inpatient ward. The conditions of interest were (1) atraumatic headache and (2) first generalized afebrile, atraumatic seizure.

Results: The measure for afebrile seizure was found to have low accuracy and low feasibility in this setting and was not tested further. The adapted measure for atraumatic headache was highly accurate in determining the encounters of interest; however, manual chart review was required to identify nonindicated brain CTs. Using this measure, 601 encounters for atraumatic headache were identified, of which 98 (16.3%) received at least 1 brain CT. We found that 14.1% of these scans were nonindicated, meaning 2% all atraumatic headache encounters received a nonindicated scan; lower than rates reported in international literature.

Conclusions: Using the tool developed in this study, rigorous measurement of the overuse of CT scans in other settings may determine the reasons for the lower rates observed in this study; inform future interventions to minimize overuse; and provide safer, higher quality care to children.

MeSH terms

  • Australia
  • Child
  • Head*
  • Hospitals
  • Humans
  • Retrospective Studies
  • Tomography, X-Ray Computed*
  • United States