Technical note: using an automated head chamber system to administer an external marker to estimate fecal output by grazing beef cattle

J Anim Sci. 2021 Sep 1;99(9):skab241. doi: 10.1093/jas/skab241.

Abstract

The objective of this experiment was to determine if titanium dioxide (TiO2) dosed through an automated head chamber system (GreenFeed; C-Lock Inc., Rapid City, SD, USA) is an acceptable method to measure fecal output. The GreenFeed used on this experiment had a 2-hopper bait dispensing system, where hopper 1 contained alfalfa pellets marked with 1% titanium dioxide (TiO2) and hopper 2 contained unmarked alfalfa pellets. Eleven heifers (BW = 394 ± 18.7 kg) grazing a common pasture were stratified by BW and then randomized to either 1) dosed with TiO2-marked pellets by hand feeding (HFD; n = 6) or 2) dosed with TiO2-marked pellets by the GreenFeed (GFFD; n = 5) for 19 d. During the morning (0800), all heifers were offered a pelleted, high-CP supplement at 0.25% of BW in individual feeding stanchions. The HFD heifers also received 32 g of TiO2-marked pellets at morning feeding, whereas the GFFD heifers received 32 g of unmarked pellets. The GFFD heifers received a single aliquot (32 ± 1.6 g; mean ± SD) of marked pellets at their first visit to the GreenFeed each day with all subsequent 32-g aliquots providing unmarked pellets; HFD heifers received only unmarked pellets. Starting on d 15, fecal samples were collected via rectal grab at feeding and every 12 h for 5 d. A two-one sided t-test method was used to determine agreement and it was determined that the fecal output estimates by HFD and GFFD methods were similar (P = 0.04). There was a difference (P < 0.01; Bartlett's test for homogenous variances) in variability between the dosing methods for HFD and GFFD (SD = 0.1 and 0.7, respectively). This difference in fecal output variability may have been due to variability of dosing times-of-day for the GFFD heifers (0615 ± 6.2 h) relative to the constant dosing time-of-day for HFD and constant 0800 and 2000 sampling times-of-day for all animals. This research has highlighted the potential for dosing cattle with an external marker through a GreenFeed configured with two (or more) feed hoppers because estimated fecal output means were similar; however, consideration of the increased variability of the fecal output estimates is needed for future experimental designs.

Keywords: GreenFeed; beef heifers; fecal output; titanium dioxide.

Publication types

  • Randomized Controlled Trial, Veterinary

MeSH terms

  • Animal Feed* / analysis
  • Animal Nutritional Physiological Phenomena*
  • Animals
  • Cattle
  • Diet / veterinary
  • Dietary Supplements
  • Medicago sativa