Estimating the Haemodynamic Streamline Vena Contracta as the Effective Orifice Area Measured from Reconstructed Multislice Phase-contrast MR Images for Patients with Moderately Accelerated Aortic Stenosis

Magn Reson Med Sci. 2022 Oct 1;21(4):569-582. doi: 10.2463/mrms.mp.2021-0001. Epub 2021 Jul 30.

Abstract

Purpose: In aortic stenosis (AS), the discrepancy between moderately accelerated flow and effective orifice area (EOA) continues to pose a challenge. We developed a method of measuring the vena contracta area as hemodynamic EOA using cardiac MRI focusing on AS patients with a moderately accelerated flow to solve the problem that AS severity can currently be determined only by echocardiography.

Methods: We investigated 40 patients with a peak transvalvular velocity > 3.0 m/s on transthoracic echocardiography (TTE). The patients were divided into highly accelerated and moderately accelerated AS groups according to whether or not the peak transvalvular velocity was ≥ 4.0 m/s. From the multislice 2D cine phase-contrast MRI data, the cross-sectional area of the vena contracta of the reconstructed streamline in the Valsalva sinus was defined as MRI-EOAs. Patient symptoms and echocardiography data, including EOA (defined as TTE-EOA), were derived from the continuity equation using TTE.

Results: All participants in the highly accelerated AS group (n = 19) showed a peak velocity ≥ 4.0 m/s in MRI. Eleven patients in the moderately accelerated AS group (n = 21) had a TTE-EOA < 1.00 cm2. In the moderately accelerated AS group, MRI-EOAs demonstrated a strong correlation with TTE-EOAs (r = 0.76, P < 0.01). Meanwhile, in the highly accelerated AS group, MRI-EOAs demonstrated positivity but a moderate correlation with TTE-EOAs (r = 0.63, P = 0.004). MRI-EOAs were overestimated compared to TTE-EOAs. In terms of the moderately accelerated AS group, the best cut-off value for MRI-EOAs was < 1.23 cm2, compatible with TTE-EOAs < 1.00 cm2, with an excellent prediction of the New York Heart Association classification ≥ III (sensitivity 87.5%, specificity 76.9%).

Conclusion: MRI-EOAs may be an alternative to conventional echocardiography for patients with moderately accelerated AS, especially those with discordant echocardiographic parameters.

Keywords: aortic stenosis; blood flow; cardiovascular magnetic resonance imaging; diagnosis.

MeSH terms

  • Aortic Valve Stenosis* / diagnostic imaging
  • Aortic Valve Stenosis* / pathology
  • Aortic Valve* / pathology
  • Hemodynamics
  • Humans
  • Magnetic Resonance Imaging / methods
  • Severity of Illness Index