Reliability and validity of the Unified Classification System for postoperative periprosthetic femoral fractures around cemented polished taper-slip stems

Bone Joint J. 2021 Aug;103-B(8):1339-1344. doi: 10.1302/0301-620X.103B8.BJJ-2021-0021.R1.

Abstract

Aims: This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems.

Methods: Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six observers (three hip consultants and three trainees) were familiarized with the UCS. Each PFF was classified on two separate occasions, with a mean time between assessments of 22.7 days (16 to 29). Interobserver reliability for more than two observers was assessed using percentage agreement and Fleiss' kappa statistic. Intraobserver reliability between two observers was calculated with Cohen kappa statistic. Validity was tested on surgically managed UCS type B PFFs where stem stability was documented in operation notes (n = 50). Validity was assessed using percentage agreement and Cohen kappa statistic between radiological assessment and intraoperative findings. Kappa statistics were interpreted using Landis and Koch criteria. All six observers were blinded to operation notes and postoperative radiographs.

Results: Interobserver reliability percentage agreement was 58.5% and the overall kappa value was 0.442 (moderate agreement). Lowest kappa values were seen for type B fractures (0.095 to 0.360). The mean intraobserver reliability kappa value was 0.672 (0.447 to 0.867), indicating substantial agreement. Validity percentage agreement was 65.7% and the mean kappa value was 0.300 (0.160 to 0.4400) indicating only fair agreement.

Conclusion: This study demonstrates that the UCS is unsatisfactory for the classification of PFFs around PTS stems, and that it has considerably lower reliability and validity than previously described for other stem types. Radiological PTS stem loosening in the presence of PFF is poorly defined and formal intraoperative testing of stem stability is recommended. Cite this article: Bone Joint J 2021;103-B(8):1339-1344.

Keywords: Cemented stem; Hip arthroplasty; Hip replacement; Periprosthetic fracture; Unified Classification System.

Publication types

  • Multicenter Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Bone Cements
  • Female
  • Femoral Fractures / classification*
  • Femoral Fractures / diagnostic imaging
  • Hip Prosthesis*
  • Humans
  • Male
  • Middle Aged
  • Observer Variation
  • Periprosthetic Fractures / classification*
  • Periprosthetic Fractures / diagnostic imaging
  • Postoperative Complications / classification*
  • Postoperative Complications / diagnostic imaging
  • Prosthesis Design
  • Radiography
  • Reproducibility of Results

Substances

  • Bone Cements