Multi-function PtCo nanozymes/CdS nanocrystals@graphene oxide luminophores and K2S2O8/H2O2 coreactants-based dual amplified electrochemiluminescence immunosensor for ultrasensitive detection of anti-myeloperoxidase antibody

J Nanobiotechnology. 2021 Jul 29;19(1):225. doi: 10.1186/s12951-021-00968-4.

Abstract

Background: Anti-myeloperoxidase antibody (anti-MPO) is an important biomarker for anti-neutrophil cytoplasm antibody (ANCA)-associated vasculitides (AAVs). However, the complicated operation procedures and insufficient sensitivity of conventional anti-MPO detection methods limit their application in monitoring efficacy of AAVs in clinical diagnosis. Herein, a dual amplified electrochemiluminescence (ECL) immunosensor based on multi-function PtCo nanozymes/CdS nanocrystals@graphene oxide (PtCo/CdS@GO) luminophores and K2S2O8/H2O2 coreactants has been fabricated for ultrasensitive detection of anti-MPO.

Results: PtCo/CdS@GO luminophores as novel signal amplification labels and nanocarriers to load rabbit anti-mouse IgG were synthesized by co-doping with Pt and Co nanozymes simultaneously with several considerable advantages, including astonishing peroxidase-like catalytic activity, high-efficiency luminescence performance and superior stability in aqueous solutions. Meanwhile, upon the K2S2O8/H2O2 coreactants system, benefiting from the efficient peroxidase-like activity of the PtCo/CdS@GO toward H2O2, massive of transient reactive intermediates could react with K2S2O8, thus obtaining higher ECL emission. Therefore, the developed ECL immunosensor for anti-MPO detection displayed good analytical performance with good concentration linearity in the range of 0.02 to 1000 pg/mL and low detection limit down to 7.39 fg/mL.

Conclusions: The introduction of multi-function PtCo/CdS@GO luminophores into the established ECL immunoassay not only was successfully applied for specific detection of anti-MPO in clinical serum samples, but also provided a completely new concept to design other high-performance luminophores. Meaningfully, the ECL immunoassay strategy held wide potential for biomarkers detection in clinical diagnosis.

Keywords: Anti-myeloperoxidase antibody; Electrochemiluminescence immunosensor; K2S2O8/H2O2 coreactants; Nanozyme; PtCo/CdS@GO luminophores.

MeSH terms

  • Animals
  • Biosensing Techniques / methods*
  • Graphite / metabolism*
  • Hydrogen Peroxide / metabolism*
  • Immunoassay / methods
  • Luminescence
  • Metal Nanoparticles
  • Mice
  • Nanoparticles
  • Peroxidase / immunology*
  • Rabbits

Substances

  • graphene oxide
  • Graphite
  • Hydrogen Peroxide
  • MPO protein, human
  • Peroxidase