Abstract
The Ti-Ca heterometallic MOF MUV-10 exhibits good dispersibility in phosphate buffer and low phosphate-induced degradation in comparison to other MOF systems. It induces no cytotoxicity towards cells of the immune system and no inmune response, making it an attractive candidate for biomedical applications and demonstrating its safe use for other applications.
Publication types
-
Research Support, Non-U.S. Gov't
MeSH terms
-
Animals
-
Biocompatible Materials / chemical synthesis
-
Biocompatible Materials / chemistry*
-
Calcium / chemistry*
-
Humans
-
Immunity
-
Materials Testing
-
Metal-Organic Frameworks / chemical synthesis
-
Metal-Organic Frameworks / chemistry*
-
Mice
-
Particle Size
-
Titanium / chemistry*
Substances
-
Biocompatible Materials
-
Metal-Organic Frameworks
-
Titanium
-
Calcium