Correlation between proximal serrated polyp detection and clinically significant serrated polyps: inter-endoscopist variability

Rev Gastroenterol Mex (Engl Ed). 2021 Oct-Dec;86(4):348-355. doi: 10.1016/j.rgmxen.2020.07.008. Epub 2021 Jul 14.

Abstract

Introduction and aims: The adenoma detection rate (ADR) is the most important quality indicator for the prevention of colorectal cancer but serrated polyps are also precursor lesions of the disease. The aim of our study was to compare the detection rate of proximal serrated polyps (PSPs) and that of clinically significant serrated polyps (CSSPs) between endoscopists and analyze the relation of those parameters to the ADR.

Methods: An observational, prospective, cross-sectional study was conducted on all patients that underwent colonoscopy at the Policlínico Peruano Japonés within the time frame of July 2015 and August 2016. The ADR and PSP and CSSP detection rates between endoscopists were compared through multivariate logistic regression and the association between those parameters was calculated through the Pearson correlation coefficient.

Results: The study included 15 endoscopists and 1,378 colonoscopies. The PSP detection rate ranged from 1.8-17% between endoscopists and had an almost perfect correlation with the CSSP detection rate (p = 0.922), as well as strongly correlating with the ADR (p = 0.769).

Conclusions: There was great variability in the PSP detection rate between endoscopists. It also had an almost perfect correlation with the CSSP detection rate and strongly correlated with the ADR. Those results suggest a high CSSP miss rate at endoscopy and a low PSP detection rate.

Keywords: Adenoma de colon; Colon adenoma; Colonoscopia; Colonoscopy; Colorectal cancer; Cáncer colorrectal; Pólipo serrato; Serrated polyp.

Publication types

  • Observational Study

MeSH terms

  • Colonic Polyps* / diagnosis
  • Colonoscopy
  • Colorectal Neoplasms* / diagnosis
  • Cross-Sectional Studies
  • Humans
  • Prospective Studies