Moving Unfavorable Small-Bowel Anatomy Away From the Prostate to Optimize Radiation Therapy Plans With the GU-Lok

Pract Radiat Oncol. 2021 Nov-Dec;11(6):510-514. doi: 10.1016/j.prro.2021.06.009. Epub 2021 Jul 5.

Abstract

Patients with localized prostate cancer comprise a large volume of treatments in radiation therapy centers. Occasionally, individual patient anatomy makes the safe delivery of an effective dose of radiation therapy challenging. We describe 2 cases of patients with a small bowel deep in the pelvis within the planning target volume with subsequent suboptimal radiation therapy treatment plans. We explore how we used the GU-Lok, a prostate immobilization device, to move the small bowel away from the prostate, and tighten target volume margins to help facilitate safe and effective treatment.

MeSH terms

  • Humans
  • Male
  • Pelvis
  • Prostatic Neoplasms* / diagnostic imaging
  • Prostatic Neoplasms* / radiotherapy
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted