A Randomized, Factorial Phase II Study to Determine the Optimal Dosing Regimen for 68Ga-Satoreotide Trizoxetan as an Imaging Agent in Patients with Gastroenteropancreatic Neuroendocrine Tumors

J Nucl Med. 2022 Mar;63(3):376-383. doi: 10.2967/jnumed.121.261936. Epub 2021 Jul 2.

Abstract

68Ga-satoreotide trizoxetan is a novel somatostatin receptor antagonist associated with high sensitivity and reproducibility in neuroendocrine tumor (NET) detection and localization. However, the optimal peptide mass and radioactivity ranges for 68Ga-satoreotide trizoxetan have not yet been established. We therefore aimed to determine its optimal dosing regimen in patients with metastatic gastroenteropancreatic NETs in a prospective, randomized, 2 × 3 factorial, multicenter phase II study. Methods: Patients received 68Ga-satoreotide trizoxetan at a peptide mass of 5-20 µg on day 1 of the study and of 30-45 µg on days 16-22, at 1 of 3 68Ga radioactivity ranges (40-80, 100-140, or 160-200 MBq). Whole-body PET/CT imaging was performed 50-70 min after each injection. The primary endpoint was the detection rate of NET lesions imaged by 68Ga-satoreotide trizoxetan relative to contrast-enhanced CT (for each of the 6 peptide mass and radioactivity range combinations). Results: Twenty-four patients were evaluated in the per-protocol analysis. The median number of lesions detected by 68Ga-satoreotide trizoxetan PET/CT or PET alone was at least twice as high as the number detected by contrast-enhanced CT across the 6 studied peptide mass and radioactivity range combinations. There were no differences between the 2 peptide mass ranges or between the 3 radioactivity ranges in the number of identified lesions. However, a trend toward a lower relative lesion count was noted in the liver for the 40- to 80-MBq range. No relationship was observed between the radioactivity range per patient's body weight (MBq/kg) and the number of lesions detected by 68Ga-satoreotide trizoxetan. The median diagnostic sensitivity of 68Ga-satoreotide trizoxetan PET/CT, based on the number of lesions per patient, ranged from 85% to 87% across the different peptide mass and radioactivity ranges. Almost all reported adverse events were mild and self-limiting. Conclusion: A radioactivity of 100-200 MBq with a peptide mass of up to 50 µg was confirmed as the optimal dosing regimen for 68Ga-satoreotide trizoxetan to be used in future phase III studies.

Keywords: 68Ga-satoreotide trizoxetan; diagnostic imaging; neuroendocrine tumors; optimal dose; somatostatin receptor antagonist.

Publication types

  • Clinical Trial, Phase II
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Gallium Radioisotopes
  • Humans
  • Intestinal Neoplasms
  • Neuroendocrine Tumors* / pathology
  • Octreotide
  • Organometallic Compounds* / adverse effects
  • Pancreatic Neoplasms
  • Positron Emission Tomography Computed Tomography / methods
  • Prospective Studies
  • Radiopharmaceuticals
  • Reproducibility of Results
  • Stomach Neoplasms

Substances

  • Gallium Radioisotopes
  • Organometallic Compounds
  • Radiopharmaceuticals
  • Octreotide

Supplementary concepts

  • Gastro-enteropancreatic neuroendocrine tumor