Quantitative phase measurements of human cell nuclei using X-ray ptychography

J Synchrotron Radiat. 2021 Jul 1;28(Pt 4):1166-1173. doi: 10.1107/S1600577521004586. Epub 2021 Jun 23.

Abstract

The human cell nucleus serves as an important organelle holding the genetic blueprint for life. In this work, X-ray ptychography was applied to assess the masses of human cell nuclei using its unique phase shift information. Measurements were carried out at the I13-1 beamline at the Diamond Light Source that has extremely large transverse coherence properties. The ptychographic diffractive imaging approach allowed imaging of large structures that gave quantitative measurements of the phase shift in 2D projections. In this paper a modified ptychography algorithm that improves the quality of the reconstruction for weak scattering samples is presented. The application of this approach to calculate the mass of several human nuclei is also demonstrated.

Keywords: X-ray; nuclei; ptychography; quantitative phase imaging; synchrotron.

MeSH terms

  • Algorithms
  • Cell Nucleus / ultrastructure*
  • Humans
  • Image Processing, Computer-Assisted / methods
  • Microscopy, Phase-Contrast / methods*
  • Synchrotrons
  • X-Ray Diffraction
  • X-Rays