Strain patterns in normal anterior talofibular and calcaneofibular ligaments and after anatomical reconstruction using gracilis tendon grafts: A cadaver study

BMC Musculoskelet Disord. 2021 Jun 18;22(1):558. doi: 10.1186/s12891-021-04444-w.

Abstract

Background: Inversion ankle sprains, or lateral ankle sprains, often result in symptomatic lateral ankle instability, and some patients need lateral ankle ligament reconstruction to reduce pain, improve function, and prevent subsequent injuries. Although anatomically reconstructed ligaments should behave in a biomechanically normal manner, previous studies have not measured the strain patterns of the anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL) after anatomical reconstruction. This study aimed to measure the strain patterns of normal and reconstructed ATFL and CFLs using the miniaturization ligament performance probe (MLPP) system.

Methods: The MLPP was sutured into the ligamentous bands of the ATFLs and CTLs of three freshly frozen cadaveric lower-extremity specimens. Each ankle was manually moved from 15° dorsiflexion to 30° plantar flexion, and a 1.2-N m force was applied to the ankle and subtalar joint complex.

Results: The normal and reconstructed ATFLs exhibited maximal strain (100) during supination in three-dimensional motion. Although the normal ATFLs were not strained during pronation, the reconstructed ATFLs demonstrated relative strain values of 16-36. During the axial motion, the normal ATFLs started to gradually tense at 0° plantar flexion, with the strain increasing as the plantar flexion angle increased, to a maximal value (100) at 30° plantar flexion; the reconstructed ATFLs showed similar strain patterns. Further, the normal CFLs exhibited maximal strain (100) during plantar flexion-abduction and relative strain values of 30-52 during dorsiflexion in three-dimensional motion. The reconstructed CFLs exhibited the most strain during dorsiflexion-adduction and demonstrated relative strain values of 29-62 during plantar flexion-abduction. During the axial motion, the normal CFLs started to gradually tense at 20° plantar flexion and 5° dorsiflexion.

Conclusion: Our results showed that the strain patterns of reconstructed ATFLs and CFLs are not similar to those of normal ATFLs and CFLs.

Keywords: Anterior talofibular ligament; Calcaneofibular ligament; Miniaturization ligament performance probe; Tension.

MeSH terms

  • Ankle Joint / surgery
  • Biomechanical Phenomena
  • Cadaver
  • Humans
  • Joint Instability*
  • Lateral Ligament, Ankle* / surgery
  • Tendons / surgery