Evaluation of total inward leakage for NIOSH-approved elastomeric half-facepiece, full-facepiece, and powered air-purifying respirators using sodium chloride and corn oil aerosols

J Occup Environ Hyg. 2021 Jul;18(7):305-313. doi: 10.1080/15459624.2021.1919685. Epub 2021 May 26.

Abstract

Recently, total inward leakage (TIL) for filtering facepiece and elastomeric half-mask respirators (EHRs) was measured according to the International Organization for Standardization (ISO) test method standard 16900-1:2014 that showed larger TIL for corn oil aerosol than for NaCl aerosol. Comparison of TIL measured for different aerosols for higher protection level respirators is lacking. The objective of this study was to determine TIL for EHRs, full-facepiece respirators, and loose-fitting and tight-fitting powered air-purifying respirators (PAPRs) using NaCl and corn oil aerosols to compare. TIL was measured for two models each of EHRs, full-facepiece respirators, and loose-fitting and tight-fitting PAPRs. After fit testing with a PortaCount (TSI, St. Paul, MN) using the Occupational Safety and Health Administration (OSHA) protocol, eight subjects were tested in the NaCl aerosol chamber first and then in the corn oil aerosol chamber, while another eight subjects tested in the reverse order. Subjects were randomly assigned to one of the two groups. TIL was measured as a ratio of mass-based aerosol concentrations inside the mask to the test chamber while the subjects performed ISO 16900-1-defined exercises using continuous sampling methods. The concentration of corn oil aerosol was measured with one light scattering photometer, alternately, and NaCl aerosol was measured using two flame photometers. Results showed the geometric mean TIL for EHR was significantly (p < 0.05) larger for corn oil aerosol than for NaCl aerosol. EHR models equipped with P100 filters showed relatively smaller TIL values than the same models with N95 filters showing that TIL was inversely related to filter efficiency. Interestingly, TIL was significantly (p < 0.05) larger for NaCl aerosol than for corn oil aerosol for PAPRs, but not for full-facepiece respirators. TIL was inversely related to fit factors of respirator types. Overall, filter efficiency and faceseal leakage determine TIL. The relative trends in TIL for the two aerosols' test methods differ between respirator types indicating that generalization of TIL for respirator types may not be appropriate when using different test agents.

Keywords: Aerosol; air-purifying respirators; efficiency; faceseal; filter penetration; total inward leakage.

Publication types

  • Randomized Controlled Trial
  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Aerosols
  • Corn Oil
  • Filtration
  • Humans
  • National Institute for Occupational Safety and Health, U.S.
  • Occupational Exposure* / prevention & control
  • Particle Size
  • Respiratory Protective Devices*
  • Sodium Chloride / analysis
  • United States

Substances

  • Aerosols
  • Sodium Chloride
  • Corn Oil