Use of a Multidisciplinary Mechanical Ventilation Weaning Protocol to Improve Patient Outcomes and Empower Staff in a Medical Intensive Care Unit

Dimens Crit Care Nurs. 2021 Mar-Apr;40(2):67-74. doi: 10.1097/DCC.0000000000000462.

Abstract

Background: Prolonged duration of mechanical ventilation is associated with higher mortality and increased patient complications; conventional physician-directed weaning methods are highly variable and permit significant time that weaning is inefficient and ineffective.

Objectives: The primary objective of this quality improvement project was to implement a registered nurse (RN)- and respiratory therapist (RT)-driven mechanical ventilation weaning protocol in a medical intensive care unit (ICU) at a tertiary care academic medical center.

Methods: This quality improvement project used a quasi-experimental design with a retrospective usual care group who underwent physician-directed (conventional) weaning (n = 51) and a prospective intervention group who underwent protocol-directed weaning (n = 54). Outcomes included duration of mechanical ventilation, ICU length of stay, reintubation rates, and RN and RT satisfaction with the weaning protocol.

Results: Patients in the RN- and RT-driven mechanical ventilation weaning protocol group had significantly lower duration of mechanical ventilation (74 vs 152 hours; P = .002) and ICU length of stay (6.7 vs 10.2 days; P = .031). There was no significant difference in reintubation rates between groups. Staff surveys indicate that both RN and RTs were satisfied with the process change.

Discussion: Implementation of a multidisciplinary mechanical ventilation weaning protocol is a safe and effective way to improve patient outcomes and empower ICU staff.

MeSH terms

  • Clinical Protocols
  • Humans
  • Intensive Care Units
  • Length of Stay
  • Prospective Studies
  • Respiration, Artificial*
  • Retrospective Studies
  • Ventilator Weaning*